摘要 热网加热器是供热汽轮发电机组的特有设备,其运行的效果将直接影响冬季供热效果,而换热管是热网加热器设备的核心,换热管的选择正确与否将是影响热网加热器正常运行和使用寿命的关键因素。根据国内某供热汽轮发电机组热网加热器换热管泄漏事故,通过组织形貌、断口分析、腐蚀性能测试等手段分析其泄露的具体原因,建议热网加热器停运期间应该进行充氮保护,不应该采取灌水保护,分析过程和结论可以供以后换热设备设计及换热管选择时参考。 Heater for heating network is the endemic equipment of heat addition steam turboset,the effectiveness of opetate will be directly effect the heat addition for winter,however Heat exchange tubes are the core of.Heater for heating network.Heat exchange tubes are chosen correctly or not is the key factor influencing the normal operation and service life of the Heater for heating network.It according to a leakage accident of heat-supply unit heating network heater's heat exchange tubes,By system patterm、ftacture analysis、corrosive nature testing etc facility to analysis of the specific reasons for the leakage,Suggest when the Heater for heating network operate should be nitrogen-filled,should not be adopt irrigation lockout,it's process of analysis and conclusions can to offer a reference for designing heating equipment and choosing heat exchange tubes.
出处 《机械设计与制造》 北大核心 2011年第7期110-112,共3页 Machinery Design & Manufacture
关键词 热网加热器 换热管 腐蚀 泄露 Heating network Heat exchange tubes Corrosion Leakage
  • 相关文献

参考文献8

  • 1DL/T12-2000火力发电厂凝汽器管选材导则,2000.
  • 2国家质量技术监督局.GB151-1999管壳式换热器.1999.
  • 3JB/TT4731-2005钢制卧式容器,2005.
  • 4GB150-1998钢制压力容器.国家技术监督局,1998.
  • 5HG/T20537.2-1992管壳式换热器用奥氏体不锈钢焊接钢管技术要求,1992.
  • 6GBl3296-2007锅炉、热交换器用不锈钢无缝钢管,2007.
  • 7GB/T17455-1998无损检测表面检查的金相复制件技术,1998.
  • 8李玲.不锈钢换热设备腐蚀分析与对策研究.长沙:湖南大学出版社,2005.

共引文献11

同被引文献31

  • 1Souto R M,Gonzalez-Garia Y,Bastos A C.Investigating corrosion Processes in the micrometric range:A SVET study of the galvanic corrosion of zinc coupled with iron. Corros.Sei . 2007
  • 2Tylor S R.Incentives for using electrochemical impedance methods in the investigation of organic coatings. Progress in Organic Coatings . 2001
  • 3Annergren I,Zou F,Thierry D.Application of localized electrochemical techniques to study kinetics of initiation and propagation during pit growth. Electrochimica Acta . 1999
  • 4R. Akid and M. Garma.Scanning vibrating reference electrode technique: a calibration study to evaluate the optimum operating parameters for maximum signal detection of point source activity. Electrochimica Acta . 2004
  • 5C. Gabrielli,S. Joiret,M. Keddam,H. Perrot,N. Portail,P. Rousseau,V. Vivier.A SECM assisted EQCM study of iron pitting. Electrochimica Acta . 2007
  • 6MC Li,YF Cheng.Corrosion of the Stressed Pipe Steel in Carbonate-Bicarbonate Solution Studied by Scanning Localized Electrochemical Impedance Spectroscopy. Electrochimica Acta . 2008
  • 7Y González-Garc?a?,G T Burstein,S González, et al.Imaging metastable pits on austenitic stainless steel in situ at the open-circuit corrosion potential. Electrochemistry . 2004
  • 8S. Lundgren,B. Kasemo.A high temperature Kelvin probes for flow reactor studies. The Review of Scientific Instruments . 1995
  • 9C. Suresh Kumar,A. Subrahmanyam and J. Majhi.Automater reed-type Kelvin probe for work function and surface photovoltage studies. The Review of Scientific Instruments . 1996
  • 10Stratmann M,Lenga Furbeth W.The Scanning Kelvin probe:a NewTechnique for the Incite Analysis of the Elimi-nation of Organic Coatings. Progress in Organic Coatings . 1996

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部