摘要
目的评价多探头联合应用在新生儿颅脑疾病中的临床应用价值。方法应用腔探头,心脏探头,浅表器官探头经新生儿前囟做多切面扫查,对三种超声探头扫查的声像图特点进行比较分析。结果超声检查新生儿共361例,检出颅脑疾病共67例,其中缺氧缺血性脑损伤34例,颅内出血27例,其中伴脑室扩张4例,化脓性脑膜炎4例,颅内占位2例。结论多探头联合应用检查可提高新生儿颅脑疾病的检出率,结合超声随访为新生儿的临床预后提供合理的诊断治疗依据。
Objective To evaluate the clinical value of Multi-probe combination in the neonatal brain disease.Methods Muliti-slice scanning from the neonatal anterior fontanel with vaginal probe,the heart of the probe and superficial organ probe respectively.Analyze and compare to the three sonographic features.Results Three hundred and sixty-one newborns were included,67 brain diseases cases were found by ultrasound,34 hypoxic-ischemic brain injury,21 intracranial hemorrhage,6 ventricular dilatation and hydrocephalus,4 purulent meninggitis and 2 intracranial space occupying.Conclusions Multi-probe combination examination can improve the detection rate of neonatal brain disease,combined with ultrasound follow-up clinical outcome for the newborn to provide a reasonable basis for the diagnosis and treatment.
出处
《医药论坛杂志》
2011年第8期6-7,10,共3页
Journal of Medical Forum