摘要
介绍了核子秤的基本工作原理和微机核子秤的硬件组成,给出了控制软件主程序的流程图及微机核子标定方法和步骤,并提出了一种用微机核子秤计量动态固体物料的方法.标定结果表明,微机核子秤的计量误差≤1% .
The basic operating principle of nulear scale and it′s hardware composition of microcomputer nuclear scale is introduced in this paper.It provides the flow diagram of the main program about the control software,the method of calibration and it′s steps is also given.A new method to measure dyramic solidstate materieals with microcomputer nuclear scale is proposed in this paper.The result shows that the error of mircrocomputer nulear scale is lower than 1%.
出处
《广西大学学报(自然科学版)》
CAS
CSCD
1999年第4期332-335,共4页
Journal of Guangxi University(Natural Science Edition)
基金
广西教委资助