摘要
主断路器是电力机车的总保护、总开关,从2008—2010年主断路器运行情况调查结果分析得出:94的主断路器故障出现在低压操纵机构,而低压操纵机构故障的98发生在启动机构和电气连锁两部分。通过分析最近3年主断路器发生故障的原因,对其进行了技术改造。
The main circuit breaker is the main protection and master switch of electrical locomotive.The analysis on the survey results of the running conditions of the main circuit breaker in 2008-2010 shows that 94% faults of the main circuit breaker occurred in the low-voltage operating mechanism,and 98% faults of low-voltage operating mechanism occurred in startup mechanism and electrical chain.And through analyzing the reasons of the faults of the main circuit breaker in the last 3 years,the technical transformation has made for it.
出处
《科技情报开发与经济》
2011年第17期225-226,共2页
Sci-Tech Information Development & Economy
关键词
8G型电力机车
主断路器
低压操纵机构
技术改造
8G electrical locomotive
main circuit breaker
low-voltage operating mechanism
technical transformation