摘要
对海域地区电气化铁道绝缘子污闪的成因和特征进行了分析,提出了污闪防治措施,指出绝缘子清扫适合短效绝缘污闪的防治,只有结合现场绝缘子类别和积污情况采取针对性的措施,才能防治绝缘污闪问题。
This paper analyzes the geneses and features of insulator contamination of electric railway in the sea area,puts forward some precaution measures for insulator contamination,and points out that the cleaning of insulator contamination is suitable for the short effect precaution of insulator contamination,and only adopting the specific measures according to the types of field insulators and the pollution degrees can prevent insulator contamination.
出处
《科技情报开发与经济》
2011年第18期197-199,共3页
Sci-Tech Information Development & Economy
关键词
海域地区
绝缘子污闪
防治措施
sea area
insulator contamination