期刊文献+

经尿道等离子柱状电极治疗后尿道狭窄疗效观察 被引量:1

Effective observation on transurethral plasma cylindrical electrode for treating posterior urethral stricture
下载PDF
导出
摘要 目的:观察经尿道等离子柱状电极治疗后尿道狭窄的疗效。方法:经尿道等离子柱状电极治疗后尿道狭窄、闭锁23例的临床资料进行术后分析。结果:23例手术均获成功,随访6~12个月,19例自行排尿通畅。最大尿流率>15 mL/s,2例6个月后复发行,二次等离子柱状电极治愈,2例1年内定期尿道扩张。结论:经尿道等离子柱状电极治疗后尿道狭窄及闭锁,具有疗效显著、并发症少、再发狭窄少等优点,是治疗创伤性后尿道狭窄安全、有效的腔内手术方法。 Objective:To evaluate the curative effect of transurethral plasma cylindrical electrode in the treatment of posterior urethral stricture.Methods:The clinical data in 23 cases of transurethral plasma cylindrical electrode for treating posterior urethral stricture and atresia were performed the postoperative analysis.Results:All cases succeeded in operation and were followed up for 6-12 months.19 cases had smooth voiding by themselves.The maximum urine flow rate(Qmax)15 mL/s.2 cases performed the second plasma cylindrical electrode treatment due to recurrence after 6 months.2 cases performed regular urethral dilation within 1 year.Conclusion:Transurethral plasma cylindrical electrode for treating posterior urethral stricture and atresia has the distinct curative effects with advantages of fewer complications and less restricture,which is safe and effective endoscopic operative method to treat traumatic posterior urethral stricture.
出处 《现代医药卫生》 2011年第14期2097-2098,共2页 Journal of Modern Medicine & Health
关键词 尿道狭窄 等离子柱状电极 外科治疗 Urethral stricture Plasma cylindrical electrode Surgery
  • 引文网络
  • 相关文献

参考文献5

二级参考文献25

  • 1李长春,赵常济,祁尤成,王俊成,陈晓,倪少滨.经尿道瘢痕切除治疗后尿道狭窄[J].临床泌尿外科杂志,1996,11(6):377-378. 被引量:11
  • 2胡志全 庄乾元 见:韩见知 庄乾元主编.尿道内切开术[A].见:韩见知,庄乾元主编.实用腔内泌尿外科学[C].广州:广东科技出版社,2001.45-47.
  • 3[1]Mcbust W K,Holtgrewe H L,Cockett A T K,et al.Transurethral prostatectomy; Immediate and postoper ative complications. Axooperative study of thirteen par ticipating institution evaluating 3885 patients . J Urol,1989,141: 243- 247.
  • 4[2]Evans J, Singer M,Coppinger S, et al. Cardiovascular performance and core temperature during transurethral prostatectomy. J Urol, 1994,152,2025 2028.
  • 5[3]Freedman M, van Molen S W, Makings E. Blood loss measurement during transurethral resection of the prostate gland. Br J Uro1,1985,57:311-314.
  • 6[4]Ekengren J ,Hahn R G. Blood loss during transurethral resection of the prostate as measured by the hemochrome photometer. J Urol, 1993,42: 501 - 505.
  • 7[5]Narayan P,Tewari A, Croker, et al. Factors affecting sizes and configuration of electrovaporization lesions ing th the prostate. J Uro1,1996,47:679-683.
  • 8[6]Elengren J, Hmhn R G. Complications during transurethral aporization. Urology, 1996,48: 424- 427.
  • 9[7]Henry B,Barre P. Electro-vaporisation of the prostate with the gyrus device. Eur Urol, 2000,37 (Suppl 2): 1 -175.
  • 10[8]Virdi,Faiyaz K, Ponnambalam Chandrasekar, et al. A prospectiverandomised study between transurethral va porisation using plasmakinetic energy. J Urol , 163(Suppl) :268-271.

共引文献656

同被引文献11

引证文献1

;
使用帮助 返回顶部