摘要
利用ATP生物发光法对丽娃河中细菌总数进行了快速检测。结果表明,丽娃河中细菌总数维持在0.72×106~1.2×107 CFU/mL,较综合整治前的水质有了明显地改善。研究了游离ATP以及浮游生物等对发光强度的影响,发现对样品采用过滤的方法进行预处理是提高ATP生物发光法精确度的一种重要手段。
To monitor the water quality of the Liwa Creek,once a heavily polluted small river in Shanghai,grab water samples were analyzed with respect to bacteria count using a quick examination method-ATP bioluminescence.The examination process involves the studies on interferences due to free ATP and plankton in the stream water and the pretreatment by filtration of water sample,which proved indispensable for increasing the measurement accuracy.
出处
《环境科学与技术》
CAS
CSCD
北大核心
2011年第7期152-155,共4页
Environmental Science & Technology
基金
上海市重大科技专项(08dz1900407)
上海市科委重大项目(09DZ1200901)
关键词
生物发光
ATP
细菌总数
快速检测
预处理
bio-luminescence
ATP
total bacteria count
fast examination
pretreatment