摘要 流动注射分析(Flow injection analysis,FIA)打破了分析化学必须在物理化学平衡条件下进行的传统,具有广泛的适应性、高效率、低消耗、重现性好及自动化程度高等优点.目前异军突起的微型全分析系统为流动注射分析理论与技术的发展注入了新的动力.本文总结了十余年来在微流控分析芯片上进行流动注射分析操作的方法与技术,对各种方法的优缺点进行了比较和分析. Flow injection analysis (FIA) revolutionized the traditional analytical chemistry which should be performed under physical and chemical equilibrium, FIA have advantages including wide applicability, high efficiency, low consumption, good reproducibility and automation over traditional analytical methods. Recently, the miniaturized total analysis system (or lab on a chip) evolved rapidly, providing opportunities for developing the theories and technologies of FIA. This paper reviews the various methods for performing FIA in microfluidic chips.
作者 徐春秀
出处 《韩山师范学院学报》 2011年第3期50-55,共6页 Journal of Hanshan Normal University
基金 韩山师范学院青年科学基金资助(基金编号:413611 413615)
关键词 微流控芯片 流动注射分析 微型全分析系统 microfluidic chip flow injection analysis miniaturized total analysis system
  • 相关文献

参考文献25

  • 1黄艳贞,方群,李丹妮.连续进样的重力驱动微流控芯片流动分析系统[J].高等学校化学学报,2004,25(9):1628-1631. 被引量:10
  • 2[丹麦]茹奇卡(Ruzicka,J·),[丹]汉森(Hansen,E·H·) 著,方肇伦等.流动注射分析[M]科学出版社,1986.
  • 3Maliwan Amatatongchai,Oliver Hofmann,Duangjai Nacapricha,Orawon Chailapakul,Andrew J. deMello.A microfluidic system for evaluation of antioxidant capacity based on a peroxyoxalate chemiluminescence assay[J]. Analytical and Bioanalytical Chemistry . 2007 (1)
  • 4DAYKIN R N C,HASWELL S J.Development of a micro flow injection manifold for the determination of orthophosphate. An-alytica Chimica Acta . 1995
  • 5GREENWAY G M,,HASWELL S J,PETSUL P H.Characterisation of a micro-total analytical system for the determination ofnitrite with spectrophotometric detection. Analytica Chimica Acta . 1999
  • 6PAN U J,LIN J J,LUO W J,et al.Sample flow switching techniques on microfluidic chips. Biosensors and Bioelectronics . 2006
  • 7PU Q S,LIU S R.Microfabricated electroosmotic pump for capillary-based sequential injection analysis. Analytica Chimica Acta . 2004
  • 8HUANG Y Z,DU W B,PAN J Z,et al.Microfluidic chip-based valveless flow injection analysis system with gravity-drivenflows. The Analyst . 2008
  • 9JAMBOVANE S,DUIN E C,KIM S K,et al.Determination of Kinetic Parameters,Km and Kcat,with a Single Experiment on aChip. Analytical Chemistry . 2009
  • 10SUN M,FANG Q.High-throughput sample introduction for droplet-based screening with an on-chip integrated samplingprobe and slotted-vial array. Lab on a Chip . 2010

二级参考文献12

  • 1黄艳贞,方群,李丹妮.可连续换样的集成化重力驱动微流控芯片连续流动分析系统[J].高等学校化学学报,2004,25(z1):143-144. 被引量:1
  • 2陈宏,方群,殷学锋,方肇伦.重力驱动多相层流分离离子选择性电极检测集成化微流控芯片系统[J].高等学校化学学报,2004,25(8):1428-1431. 被引量:4
  • 3SeilerK., FanZ. H., FluriK. et al.. Anal. Chem.[J], 1994, 66: 3485-3491
  • 4Tokeshi M. , Minagawa T. , Kitamori T.. Anal. Chem. [J], 2000, 72:1 711-1 714
  • 5Wu X., Suzuki M., Sawada T. et al.. Anal. Sci. [J], 2000, 16:321-323
  • 6Weigl B. H. , Bardell R. , Schulte T. et al.. Proceedings of MicroTAS[C], Enschede, 2000:299-302
  • 7Fang Q., XuG. M., FangZ. L.. Anal. Chem.[J], 2002, 74: 1 223-1 231
  • 8FANGQun(方群) DUWen-Bin(杜文斌) FANGZhao-Lun(方肇伦).Chinese Patent[P].03 114 734.8[P].2003.
  • 9FANGZhao-Lun(方肇伦).Microfluidic Analytical Chips(微流控分析芯片)[M].Beijing:Science Press,2003.104.
  • 10FANGQun(方群) LIDan-Ni(李丹妮) XUGuang-Ming(徐光明)etal.The 1st National Symposium onx-TAS(首届全国微摘要集)[C]..全分析会议论文[C].Beijing,2002.44-45.

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部