摘要 中国高通量工程试验堆(HFETR)在流量反转过程中,堆芯热工参数的变化会影响到反应堆的安全运行。为此本文利用RELAP5/MOD3程序建立了HFETR模型,进行了相关的研究,得出HFETR强迫循环向自然循环转换的最大允许功率为850 kW,自然循环向强迫循环过渡的时刻由压力壳上部水温决定。研究结果表明,现运行模式能保证反应堆的运行安全,为以后运行模式的完善提供了支持。 In the flow reverse of High Flux Engineering Test Reactor(HFETR),the change of the reactor core's thermal parameters affects the safety of the reactor operation.So the model of HFETR by the RELAP5/MOD3 code was established and relevant research was conducted.The study results indicate that the maximum permissible power for the conversion from forced circulation to natural circulation is 850 kW,the time for the conversion from natural circulation to forced circulation is decided by the upper coolant temperature.The results show that the recent operating mode can guarantee the safe operation of the reactor,and the data provide the support for the more perfect operation mode in the future.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2011年第6期682-687,共6页 Atomic Energy Science and Technology
关键词 HFETR 自然循环 流量反转 强迫循环 HFETR natural circulation flow reverse forced circulation
  • 相关文献

参考文献2

  • 1强辉,吴英华,卜永熙,等.HFETR运行限值和运行条件[c]//高通量工程试验堆(HFETR)运行十年论文集.成都:四川科学技术出版社,1990:125-130.
  • 2徐传效,周永茂,钱锦辉,等.高通量工程试验堆(HFETR)[c]∥高通量工程试验堆(HFETR)运行十年论文集.成都:四川科学技术出版社,1990:1-12.