采用混凝沉淀-水解酸化-二级接触氧化工艺处理东莞某制衣公司废水。运行结果表明,在pH调节为7~7.5,某混凝剂投加量为20mg/L,水解酸化停留时间为6h,有机负荷为1.5kgBOD5/(m^3.d)时,COD、BOD5和色度的平均去除率分别为86%、92%YO90%,出水水质达到《污水综合排放标准》(688978—1996)二级标准。给出了混凝加药单元及接触氧化池单元的调试方法,并对可能出现的问题提出了解决的措施。
The integrated process of the coagulating sedimentation, acidification hydrolization and secondary bio-contact oxidation was adapted to treat the wastewater of a garment factory in Dongguan. The results indicated that the removal ratio of COD, BOD~ and chroma reached 86%, 92% and 90% respectively under the as following conditions. The pH value is at the range of 7-7.5; the concentration of the coagulating agent is 20 rag/L; the residence time of acidification hydrolization is 6 h, and the organic load is 1.5kg BODJ(m^3.d). After the treatment, the quantity of effluent can satisfy the demand of the Secondary Standard of Integrated Wastewater Discharge Standard (GB8978-1996) in China. The adjustment operation of the coagulating and bio-contact oxidation was introduced, and the solutions for the potential problems in this treatment process were supplied also.
出处
《能源环境保护》
2011年第3期36-41,共6页
Energy Environmental Protection
基金
厦门理工学院人才引进科研资助项目(YKJ10031R)
关键词
制衣废水
混凝沉淀
水解酸化
接触氧化
Garment factory wastewater
Coagulating sedimentation
Acidification hydrolization
Bio-contact oxidation