摘要 变压器的绝缘电阻是反映设备绝缘状况的一个重要参数,其测试过程易受温度、湿度等环境因素、污秽及电压等级的影响。现有规程中给出了变压器绝缘电阻温度换算的规定,然而在大量试验过程中发现其有不适用性。通过对大量测试结果的分析评价,针对变压器绝缘在不同温度下的介电特性,在不计及其他环境因素变化的条件下,分析并通过试验验证绝缘电阻与温度的内部规律,进而分析绝缘电阻的影响因素,就温度换算对现有规程的执行提出建议,供变压器绝缘状况的评估工作参考。 Transformer insulation resistance is an important parameter reflecting the equipment insulation condition. Insulation resistamc testing process is susceptible to environmental factors such as temperature, humidity, defacing and voltage levels. Large number of lesting results indicated that the existing rules for the temperature conversion of transtormer insulation resistance are not applicable. According to the changes of dielectric properties of transformer insulation under different temperatures, the relationship between insulation resistance and temperature was analyzed and tested without taking account of other factors. Recommendations on the implementation of the existing rules were given, which is usetul to transformer insulation status assessment.
出处 《中国电力》 CSCD 北大核心 2011年第7期26-30,共5页 Electric Power
关键词 变压器 绝缘电阻 温度 电介质极化 transformer insulation resistance temperature dielectric polarization
  • 相关文献

参考文献6

  • 1GB/T6451-2008,油浸式电力变压器技术参数和要求[S].
  • 2GB 50150--2006电气装置安装工程电气设备交接试验标准[S].
  • 3DL/T596-1996.电力设备预防性试验规程[S].[S].,..
  • 4张洛群,杨玉敏,陈楚雄.新安装500kV变压器介损分析与判断[J].东北电力技术,2002,23(9):22-25. 被引量:3
  • 5胡启儿.变压器试验技术[M].北京,中国电力出版社.2010.
  • 6西南电业管理局试验研究所.高压电气没备试验方法[M].北京:水利电力出版社.1984.

二级参考文献1

  • 1DL/T 596-1996.电力设备预防性试验规程[S],1996.

共引文献343

同被引文献70

引证文献8

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部