摘要
以某再生水厂改造工程为背景,在对各种除盐工艺进行比较后,选择离子交换和反渗透两种工艺进行了详细的工艺技术及经济比选,并最终选择了反渗透系统作为除盐工艺,实际数据证明,反渗透系统运行稳定,产水水量、水质达到设计要求。
Taking the reconstruction project of some regenerated water works as the background, the paper undertakes the detailed craft tech- nique and economic selection of ion-exchange and the reverse osmosis after comparing all sorts of desalting craft, selects the reverse osmosis sys- tem as the desalting craft, and proves by the factual data that the reverse osmosis system has stable operation, and its water volume and quality can reach the design requirements.
出处
《山西建筑》
2011年第21期107-108,共2页
Shanxi Architecture
关键词
再生水厂
除盐
工艺选择
运行
regenerated water works, desahing, craft selection, operation