摘要 由于采动应力会导致煤层顶板垮断冒顶、巷道底鼓以及冲击矿压和煤与瓦斯突出发生,因此采用现场应力测试和数值模拟相结合的方法,研究了焦家寨煤矿三软厚煤层综采面采动应力分布规律,结果表明:距离工作面0—12 m为超前支承压力降低区、12—40 m为增高区、40 m以外为稳定区,应力集中系数为1.4-1.7;侧向支承压力在0—14 m形成应力降低区,在14—36 m形成应力增高区,36 m以外进入应力稳定区。 The mining stress would cause the roof and floor broken and failure,spalling and roof falling,floor heave of the seam and would cause the mine pressure bumping and the coal and gas outburst occurred.The site stress measurement and the numerical simulation combined method was applied to study the mining stress distribution law of the fully mechanized coal mining face in the seam with soft roof,soft coal and soft floor in Jiaojiazhai Coal Mine.The results showed that the pilot support pressure and stress reducing area was at a distance of 0—12 m in front of the coal mining face,the stress increased area was at a distance of 12—40 m in front of the coal mining face,the stress stable area was beyond 40 m in front of the coal mining face and the stress concentration coefficient was 1.4-1.7.There was a stress reduced area formed within a scope of 0—14 m of the lateral support pressure area,a stress increased area formed in the scope of 14—36 m and the stress sable area formed beyond 36 m.the analysis showed that the deformation and failure of the air return gateway in No.51109 coal mining face in Jiaojiazhai Mine was located under the lateral support pressure increased area formed by the above seam mining face.
出处 《煤炭科学技术》 CAS 北大核心 2011年第7期21-24,共4页 Coal Science and Technology
关键词 三软厚煤层 采动应力 综放开采 应力测试 seam with soft roof soft coal and soft floor mining stress fully mechanized top coal caving mining stress measurement
  • 相关文献

参考文献9

二级参考文献42

共引文献353

同被引文献127

引证文献19

二级引证文献94

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部