核磁共振成像系统的质量保证与质量控制 被引量:17

Quality Assurance and Quality Control in Magnetic Resonance Imaging System
下载PDF
导出
摘要 本文概括介绍了核磁共振成像系统在安装前后和使用过程中实行质量测试的重要性和具体方法步骤。主要包括系统验收测试、日常检查、基本测试,以及年度系统评估。建立一个完整合理的质量保证、质量控制方案,并能按时全面执行这一方案,对于保证磁共振成像系统的高质、高效运行,提高临床和科研能力起到十分重要的作用。 This article introduced the concept and procedures of quality assurance(QA) and quality control(QC) in Magnetic Resonance Imaging(MRI) system during its installation and routine clinical uses.It is mainly focused on system acceptance testing,daily system check and QC test and annual system performance testing.It is important to build a comprehensive and accurate QA/AC program in a MRI facility,and the exact implementation of this program will essentially improve the quality and efficiency for both clinical and research studies using the MRI techniques.
作者 邓洁
出处 《中国医疗设备》 2011年第7期13-20,26,共9页 China Medical Devices
关键词 核磁共振 验收测试 质量保证 质量控制 医学影像设备 magnetic resonance imaging acceptance testing quality assurance quality control medical inaging equipment
  • 相关文献

参考文献16

  • 1Jackson EF,Bronskill MJ, Drost DJ, et al. Acceptance Testing and Quality Assurance Procedures for Magnetic l,kesonance Imaging Facilities: Report of AAPM MR Subcommittee Task Group I[J]. AAPM Report No,2010,10:100.
  • 2Price RR, Axel L, Morgan T, et al.Quality assurance methods and phantoms for magnetic resonance imaging: Report of AAPM nuclear magnetic resonance Task Group No.l[J].Med Phys,1990,17(2):287-295.
  • 3Och JG, Clarke GD, Sobol WT, et al. Acceptance testing ofmagnetic resonance imaging systems: Report of AAPM Nuclear Magnetic Resonance Task Group No,6[J].Med Phys,1992, 19(1):217-229.
  • 4American College of Radiology(ACR).Site Scanning Instructions for Use of the MR Phantom for the ACRTM MRI Accreditation Program[J].2008,11 : 121.
  • 5American College of Radiology (ACR). MRI Accreditation Program Phantom Test Guidance[R].Reston:American College of Radiology,2006.
  • 6American College of Radiology (ACR). MRI QualiW Control Manual 2004[R]. Reston:VA ACR, 2004.
  • 7Kanal E, Barkovich AJ, Bell C, et al. ACR guidance document for safe MR practices[J].AJR Am J Roentgenol,2007,188 (6):1447-1474.
  • 8Evans JB.Structural floor vibration and sound isolation design for a magnetic resonance imaging system[J]. J Building Acoustics, 2005,12:207-223.
  • 9Chen HH, Boykin RD, Clarke GD, et al.Routine testing of magnetic field homogeneity on clinical MRI systems[J]. Med Phys ,2005,33(11):4299-4306.
  • 10NEMA-MS-1. Determination of Signal-To-Noise Ratio (SNR) in Diagnostic Magnetic Resonance Imaging. NEMA MR Standards:MS 1-2008[R].Rosslyn, VA:National ElectricalManufacturers Association, 2008.

同被引文献125

引证文献17

二级引证文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部