摘要 并联型三相四线制有源电力滤波器(APF)具有良好的滤波效果,其关键是能准确地补偿谐波电流,在此问题上谐波电流检测显得至关重要。为此,提出一种基于自适应有限脉冲响应(FIR)预测与FBD电流检测相结合的电流检测算法,通过Matlab仿真证明了理论的正确性,并在一台15 kVA的样机上验证了这种新算法的可行性与有效性。 Shunt three-phase four-wire active power filter(APF) has a good filtering effect,the key is that the har-monic current can be compensated accurately and current testing is critical on this issue.Therefore,a method based on an current testing algorithm of combining adaptive finite impulse response(FIR) with FBD is proposed and Matlab simulation is done accurately.It is proves that the new algorithm is feasible and effective by the experimental results in a 15 kVA APF prototype.
出处 《电力电子技术》 CSCD 北大核心 2011年第6期47-49,共3页 Power Electronics
关键词 有源电力滤波器 三相四线制 电流检测 谐波补偿 active power filter three-phase four-wire current detection harmonic compensation
  • 相关文献

参考文献5

二级参考文献28

共引文献42

同被引文献3

  • 1刘金琨.滑模变结构控制MATLAB仿真[M].北京:清华大学出版社.2012.
  • 2Suttichai Saetieo, Rajesh Devaraj, Torrey.The Design and Implementation of a Three-phase Active Power Filter Based on Sliding Mode Control[J].IEEE Trans. on In- dustry Applications, 1995,31 ( 5 ) : 993-1000.
  • 3庞健,惠晶.改良FBD法在谐波电流检测中的应用研究[J].电力电子技术,2012,46(1):63-65. 被引量:4