期刊文献+

门控分幅相机增益均匀性优化设计 被引量:1

Optimization of framing camera gain uniformity
下载PDF
导出
摘要 利用宽度渐变微带线进行了门控分幅相机增益不均匀性修正技术研究。建立了渐变微带线修正的物理模型,通过特性阻抗调配补偿幅度衰减,设计了特种渐变微带线参数。比较了特种曲线渐变微带线与传统直线渐变微带线的修正效果。在0~4GHz带宽范围内,特种曲线渐变微带补偿后,电压幅度不一致性由15.0%降低至1.6%,增益不一致性由70%降低到8%。对于当前使用的分幅相机,微带线宽度由6.00mm渐变到4.45mm就能有效地降低门控分幅相机增益的不一致性。 Correction of gain nonuniformity is researched by using taper microstrip.The physical correction model is founded.The taper microstrip compensates the magnitude attenuation by compensating the impedance of microstrip.The taper microstrip is designed.The correction results of curve taper microstrip and straight taper microstrip are compared with each other.The voltage nonuniformity decreases from 15.0% to 1.6% and the gain nonuniformity decreases from 70% to 8% with curve taper microstrip compensation while the frequency of pulse is between 0 and 4 GHz.The taper microstrip with width from 6.00 mm to 4 mm has a good effect of correcting the gain nonuniformity for current framing camera.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2011年第6期1459-1462,共4页 High Power Laser and Particle Beams
基金 国家高技术发展计划项目
关键词 分幅相机 微通道板 渐变微带线 电压幅度 增益 不一致性 framing camera micro channel plate taper microstrip voltage magnitude gain nonuniformity
  • 相关文献

参考文献10

  • 1成金秀,温天舒,朱宗元,杨存榜,常增虎,山冰,侯继东.MCP选通X射线皮秒分幅相机在ICF中的应用[J].强激光与粒子束,1996,8(1):73-77. 被引量:10
  • 2Kilkenny J D. High speed proximity focused X-ray cameras[J]. Laser and Particle Beams, 1991, 9(1):49-69.
  • 3Horsfield C J, Parker K W, Rothman S D, et al. Correcting for gain effects in an X-ray framing camera in a cylindrical implosion experiment [J]. RevSciInstrum, 2004, 75(10) :3947-3949.
  • 4袁铮,刘慎业,曹柱荣,肖沙里,黎航,张海鹰,王丽伟.门控分幅相机增益衰减特性[J].强激光与粒子束,2009,21(5):704-708. 被引量:3
  • 5McCarville T, Fulkerson S, Booth R, et al. Gated X ray intensifier for large format simultaneous imaging[J]. Rev Sci Instrum, 2005, 76:103501.
  • 6Rochau G A, Dunham G S, Keister J W, et al. Energy dependent sensitivity of microchannel plate detectors[J]. Rev Sci lnstrum, 2006, 77 : 10E323.
  • 7Watt R G , Oertel J , Archeluta T, Gated X ray imager gain correction using a tapered microchannel-plate stripline[J]. Rev Sci Instrum, 1994, 65(8) :2585-2586.
  • 8Watt R G , Oertel J , Archeluta T, Gated X ray imager gain correction using a tapered microchannel-plate stripline[J]. Rev Sci Instrum, 1994, 65(8) :2585-2586.
  • 9Oertel J A, Archuleta T N, Schrank L S. The large format X-ray imager[J]. Rev Sci lnstrum, 2001, 72(1); 701-704.
  • 10PozarDM.微波工程[M].5版.北京:电子工业出版社,2006:124-125.

二级参考文献13

  • 1曹柱荣,丁永坤,张海鹰,白晓红,刘百玉,白永林.X射线分幅相机真空弧放电损害研究[J].强激光与粒子束,2007,19(2):321-326. 被引量:7
  • 2Lieber A J. Nanosecond gating of proximity focused channel plate intensifiers[J]. Rev Scic Instrum ,1972,43(1):104.
  • 3Fehl D L,Chang J,Kuswa G W, et al. Five-frame, X-ray camera for charged particle, inertial confinement fusion studies [J]. Rev Sci Instrum ,1980,51(3) :292.
  • 4Young B K F, Stewart R E, Woodworth J G,et al. Experiment demonstration of a 100-ps microchannel plate framing camera[J]. Rev Sci Instrum, 1986 ,57(11):2729-2732.
  • 5Kauffman Z F, Kilkenny R L, Wielwald J D,et al. A new multichannel soft X-ray framing camera for fusion experiments[J]. Rev Sci Instrum, 1992,63(10):5124.
  • 6Kilkenny J D. High speed proximity focused X-ray cameras[J]. Laserand Particle Beams ,1991,9(1):49-69.
  • 7Pawley C J, Deniz A V. Improved measurements of noise and resolution of X-ray framing cameras 1-2 keV[J]. Rev Sci Instrum, 2000,71 (3) : 1286-1295.
  • 8MeCarville T, Fulkerson S, Booth R, et al. Gated X-ray intensifier for large format simultaneous imaging[J]. Rev Sci Instrum, 2005,76: 103501
  • 9Horsfield C J,Parker K W,Rothman S D,et al. Correcting for gain effects in an X-ray framing camera in a cylindrical implosion experiment [J]. Rev Sci Instrum, 2004,75(10) :3947-3949.
  • 10Andreev A A, Hidetoshi N K, Limpouch J. Ferntosecond X-ray line emission from specially designed targets irradiated by short laser pulses [C]//Proc of SPIE. 2004, 5196:326-336.

共引文献10

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部