期刊文献+

动力髋螺钉联合防旋螺钉内固定治疗高龄股骨粗隆间骨折体会 被引量:3

下载PDF
导出
摘要 目的观察使用动力髋螺钉(DHS)联合防旋螺钉内固定治疗高龄股骨粗隆间骨折的效果。方法使用DHS联合防旋螺钉内固定治疗高龄股骨隆间骨折患者37例,随访4~48个月,平均21个月。结果所有病例骨折愈合良好,2例髋内翻畸形伴螺钉松动移位,1例患肢外旋畸形。本组优26例,良8例,可3例,优良率为93%。结论 DHS联合防旋螺钉内固定治疗高龄股骨粗隆间骨折,可有效防止单纯动力髋内固定不能控制骨折端的旋转应力的弊端,并能加强骨折固定牢固度,有利于减少并发症,提高临床治愈率,是治疗股骨粗隆间骨折较理想的方法。
作者 张拥军
出处 《现代中西医结合杂志》 CAS 2011年第21期2668-2669,共2页 Modern Journal of Integrated Traditional Chinese and Western Medicine
  • 相关文献

参考文献5

  • 1黄公怡 王福权.鹅头钉治疗股骨粗隆间骨折的疗效分析.中华骨科杂志,1984,4(6):349-53.
  • 2崔晓明,孙世毅.DHS治疗转子间骨折体会[J].吉林医学,2007,28(18):1982-1982. 被引量:2
  • 3Alobaid A,Harvey EJ,Elder GM,et al. Minimally invasive dynamic hip screw: prospective randomized trial of two techniques of insertion of a standard dynamic fixation device [ J]. J Orthop Trauma, 2004,18(4) :207.
  • 4Buciuto R, Hammer R. RAB - plate versus sliding hip screws for unstable trochanteric hip fractures: stability of the fixation and modes of failures-radiographic analysis of 218 fractures[ J]. J Trauma,2001,50(3) :545.
  • 5张经纬,蒋垚,张先龙,冯建翔,杨立峰,赵刘军,吴志军,黄雷,曾炳芳.股骨转子间骨折不同手术方法比较[J].中华骨科杂志,2005,25(1):7-11. 被引量:389

二级参考文献14

  • 1Jensen JS, Miehaelsen M. Troehanteric femoral fractures treated with McLaughlin Osteosynthesis. Acta Orthop Stand, 1975, 46: 795-803.
  • 2Parker M J, Palmer CR. A nev, mobility score for predicting mortality after hip fracture. J Bone Joint Surg (Br), 1993, 75: 797-798.
  • 3Kitamura S. Hasegawa Y, Suzuki S. et al. Functional outcome after hip fracture in Japan. Clin Orthop, 1998, (348): 29-36.
  • 4Rogers FB, Shackford SR, Kelleer MS. Early fixation reduces morbidity and mortalilv in elderly patients with hip fractures from low-impact falls. J Trauma, 1995, 39: 261-265.
  • 5Baixauli F, Vicent V, Baixauli E, et al. A reinforced rigid fixation device for unstable intertrochanteric fractures. Clin Orthop. 1999,(361): 205-215.
  • 6Parker MJ. Trochanteric hip fractures: fixation failure commoner with femoral medialization: a comparison of 101 cases. Acta Orthop Seand, 1996, 67: 329-332.
  • 7Simmermacher RK, Rosch AM, Van der Werken C. The AO/ASIF-proximal femoral nail(PFN): a new device for the treatment of unstable proximal femoral fracture. Injury, 1999. 30: 327-332.
  • 8Sadowski C, Lubbeke A, Saudan M, et at. Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or 95 ° screw-plate. J Bone Joint Surg (Br), 2002,84: 372-381.
  • 9Herrra A. Domingo LJ, Catvo A, et at. A comparative study of the trochanteric fractures treated with the Gamma nail or the proximal nail. Int Orthop, 2002, 26: 365-369.
  • 10Buciuto R, Hammer R, RAB-plate versus sliding hip screws for unstable trochanteric hip fractures: stabitity of the fixation amt modes of failure-radiographic analysis of 218 fractures. J Trauma, 2001,50: 545-550.

共引文献413

同被引文献25

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部