摘要 目的探讨多层螺旋CT对不同眼球异物立体精确定位的灵敏度和特异性。方法兔子10只20眼,行手术分别放入不同数量铁屑、竹屑、玻璃碎片,应用不同检测方式和多层螺旋CT进行扫描诊断,对比检测效果。结果多层螺旋CT对20颗铁屑异物的显示率为100%,能较好地显示铁屑的位置、大小和形态;对10颗玻璃碎屑的显示率为40%(4颗);对10颗竹屑的显示率为20%(2颗)。结论多层螺旋CT检查具有无损伤、简便快速的优点,其三维立体影像对高密度眼内异物的定位更加准确可靠,在临床操作中可以给手术大夫提供更准确详细的信息,提高手术的准确性和成功率,易被临床接受。 Objective To evaluate the sensitivity and specificity of multi-slice spiral CT in the three-dimensional precise positioning of different intra-ocular foreign body. Methods 10 rabbits with 20 eyes,and put different numbers of iron,bamboo shavings and broken glass in the eyes by surgery,then used different testing methods and diagnostic multi-slice spiral CT scanned,compared the detection. Results The display rate of the multi-slice spiral CT to 20 of iron was 100%,which showed that it could show the location,size and shape of iron;the display rate of the multi-slice spiral CT to 10 glass fragments and 10 Bamboo was 40%(4) and 20%(2) . Conclusion The multi-slice spiral CT had obvious advantages for precise location to high density of intra-ocular foreign body and it should combine with other methods to precise positioning of non-metallic intra-ocular foreign body.
出处 《海南医学》 CAS 2011年第14期88-89,共2页 Hainan Medical Journal
关键词 眼内异物 多层螺旋CT 精确定位 Intraocular foreign body Multi-slice spiral CT Precise positioning
  • 相关文献

参考文献5

二级参考文献16

  • 1林瑶敏,袁小平,顾建军,吴楚忠,林军,聂时淮.92例眼眶异物的影像诊断价值分析[J].影像诊断与介入放射学,2005,14(4):212-215. 被引量:11
  • 2张金嵩,张效房.眼内异物的诊断与摘出手术[J].中华眼科杂志,1996,32(1):70-75. 被引量:10
  • 3王晋祖,陆建平,张伟英,汪浩,储浩,汪波,刘伟.多层螺旋CT对眼球异物的检出和定位价值[J].中国医学影像学杂志,2007,15(2):81-85. 被引量:5
  • 4吴恩惠.医学影像诊断学.第1舨.北京:人民卫生出版社.2004.925.
  • 5李果珍.临床CT诊断学.第1版.北京:中国科学技术出版社.2006.161.
  • 6Roters S, Szurman P, Hermes S, Thumann G, Bartz Schmidt KU, Kirchhof B. Outcome of combined penetrating keratoplasty with vitreoretinal surgery for management of severe ocular injuries. Retina,2003;23(1):48-56
  • 7Chiquet C, Zech JC, Gain P, Adeleine P, Trepsat C. Visual outcome and prognostic factors after magnetic extraction of posterior segment foreign bodies in 40 cases. Br J Ophthalmol,1998;82(7):801-806
  • 8Ta CN, Bowman RW. Hyphema caused by a metallic intraocular foreign body during magnetic resonance imaging. Am J Ophthalmol,2000;129:533-534
  • 9Deramo VA, Shah GK, Baumal CR, Finenan MS, Correa ZM, Benson WE,Rapuano C J, Cohen E J, Augsburger JJ. Ultrasound biomicroscopy as a tool for detecting and localizing occult foreign bodies after ocular trauma. Ophthalmology,1999;106:301-305
  • 10Dass AB, Ferrone PJ, Chu YR, et al. Sensitivity of spiral computed tomography scanning for detecting intraocular forengn bodies,Ophthalmology, 2001, 108 (12): 2326

共引文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部