摘要
利用钽丝作为热线的瞬态双热线系统对温度区间233~373 K、压力区间为0.1~30 MPa的液相二乙二醇单甲醚(diethylene glycol monomethyl ether,DGMME)的导热系数进行了实验研究,并将实验数据拟合为温度和压力的关联式。实验数据与导热系数关联式计算结果的标准偏差和最大偏差分别为0.23%和0.86%,导热系数的合成标准不确定度小于土1.0%。
The thermal conductivity of liquid diethylene glycol monomethyl ether (DEGMME) was measured from 233 to 373 K and pressures from 0.1 to 30 MPa, by the transient hot-wire technique employing two anodized tantalum hot wires. The experimental data was correlated as a function of temperature and pressure. The absolute average deviation and the maximum deviation of the experimental results from the correlated equation were 0.23% and 0.86%. The uncertainty of the thermal conductivity was 11.0% with a coverage factor of k ±2.
出处
《工程热物理学报》
EI
CAS
CSCD
北大核心
2011年第8期1265-1268,共4页
Journal of Engineering Thermophysics
基金
国家高技术研究发展计划(No.2009AA05Z107)
高等学校博士学科点专项科研基金(No.20090201110008)
关键词
导热系数
瞬态热线法
二乙二醇单甲醚
thermal conductivity
transient hot-wire method
diethylene glycol monomethyl ether