摘要 为了研究在不同功率热源的情况下,自然通风和机械通风对房间内温度场的影响程度.对房间四壁和顶棚不同位置开口和不同尺寸,在自然通风情况下房间内温度场受到的影响进行了实验比较.结果说明,自然通风对流交换主要由热源附近空气受热后卷吸侧向窗口外部的冷空气进入产生,开天窗时才会有明显散热效果.对于墙壁侧向开口情况,出现空间内部上下层之间冷热分层明显,但散热效果不明显.实验还显示出机械通风比自然通风气流扰动强度要大很多.在实际工程设计中,采用顶窗和侧窗的兼备考虑,才有最适合的自然通风效果. To study the effects of natural and mechanical ventilation on the indoor temperature under heat sources of different powers,experiments were carried out to compare the indoor temperature field with natural ventilation under different conditions,using various vent sizes and locations on the walls or ceiling.The results show that natural ventilation is mainly due to cool air from a side-window resulting from the entering of air rising near the heat source.Therefore,it is highly effective to heat dissipation with the vent opening being on the roof.When the vent is vertical,the layers of hot air and cool air stratify vertically;however,the effect of heat dissipation is not evident yet.Furthermore,it was found that the air perturbation is much stronger for mechanical ventilation than that for natural ventilation.It was suggested that the most efficient ventilation is with side-windows and skylights all in considering in the practical engineering.
作者 杨春英 董惠
出处 《哈尔滨工程大学学报》 EI CAS CSCD 北大核心 2011年第2期173-177,222,共6页 Journal of Harbin Engineering University
基金 中央高校基本科研业务费专项资金资助项目(HEUCF100206)
关键词 热源 自然通风 机械通风 heat sources natural ventilation mechanical ventilation
  • 相关文献

参考文献7

二级参考文献22

  • 1沈晋明.室内污染物与空气品质评价[J].通风除尘,1995,14(4):10-13. 被引量:78
  • 2祟耀庆.供暖通风设计手册[M].北京:中国建筑工业出版社,1994.628-636.
  • 3JIANG Yi. State-space method for the calculation of air-conditioning loads and the simulation of thermal behavior of the room [J]. ASHRAE Trans, 1982, 88(2) : 122 - 141.
  • 4HONG Tianzhen, JIANG Yi. New multizone model for the simulation of building thermal performance [J]. Building and Environment, 1997, 32(2): 123-12.
  • 5Blondeau P, Sperandio M. Night ventilation for building cooling in summer [J]. Solar Energy, 1997, 61(5): 327 -335.
  • 6Geros V, Santamouris M. Experimental evaluation of night ventilation phenomena [J]. Energy and Buildings, 1999, 29(2), 141 - 154.
  • 7JIANG Yi, CHEN Qingyan. Study of natural ventilation in buildings by large eddy simulation {J]. Wind Eng and Indu Aerodynamics, 2001, 89:1155-1178.
  • 8Li An-Gui, Jones P. Developments in strategies used for natural and mechanical ventilation in China [J]. Indoor Built Environment,2000, (9): 65-74
  • 9Yuguo Li, Angelo Delsante. Natural ventilation induced bycombined wind and thermal forces [J]. Building and Environment. 2001, (1):33-42
  • 10F Linden. The fluid mechanics of natural ventilation [J]. Fluid Mech, 1999, (2): 201-238