摘要 医院的供配电方式与其他民用建筑有较大区别,为了保证对该场所内的医疗电器提供一个安全可靠的电源,以确保病人的安全,本系统采用IT供电系统,运用PLC逻辑控制及通讯的优势,替换传统低压控制电路器件,即节省了成本,由提高了系统的可靠性和操作性。 There was difference of the means of the power supply between the the hospital and the civil construction.In order to ensure the safety and reliability of source of the medical device and guarantee safety of patients,the system was designed by IT power supply system,which use the advantages of PLC logic control to replace the traditional low-voltage control circuit devices,which can save cost and improve maintainability and operability and extend the function.
作者 吴晓亮
出处 《河北省科学院学报》 CAS 2011年第2期49-52,共4页 Journal of The Hebei Academy of Sciences
关键词 低压配电 断路器级联 PLC IT供电系统 Low-voltage distribution Circuit breaker cascade PLC IT power supply system