期刊文献+

模拟混凝土孔溶液中钢筋腐蚀的稳态与瞬态电化学方法比较 被引量:3

Comparison of Stationary and Transient Electrochemical Measurements for Steel Corrosion in Simulated Concrete Pore Solution
原文传递
导出
摘要 应用电化学测试方法,研究含氯盐且pH值不同的模拟混凝土孔溶液中的钢筋腐蚀过程.介绍了稳态和瞬态电化学测试方法:线性极化(LPR)、电化学阻抗谱(EIS)和恒电流脉冲(GPM),通过测试不同模拟液中钢筋的腐蚀,对比分析不同电化学方法测得的极化电阻值.结果表明,这三种方法测出的钢筋极化电阻变化规律一致,均能较好地预测钢筋腐蚀速率. The corrosion behavior of reinforced steel in simulated concrete pore solutions with chloride and different pH values was studied by electrochemical methods. Stationary and transient electrochemical methods, such as linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS) and galvanostatic pulse measurement (GPM) were reviewed, and the obtained polarization resistances by means of different methods in different simulated concrete pore solu- tions were comparatively analyzed. The results indicate that the polarization resistances obtained by these methods are similar and comparable, which means these methods can give a reliable assessment on reinforced steel corrosion.
出处 《腐蚀科学与防护技术》 CAS CSCD 北大核心 2011年第4期323-329,共7页 Corrosion Science and Protection Technology
基金 国家重点基础研究发展计划项目(2009CB623203)资助
关键词 钢筋腐蚀 模拟混凝土孔溶液 线性极化 电化学阻抗谱 恒电流脉冲 reinforced steel corrosion simulated concrete pore solution LPR EIS GPM
  • 相关文献

参考文献9

  • 1Bohni H. Corrosion in Reinforced Concrete Structure[M]. England: Woodhead Publishing Ltd, 2005: 42.
  • 2胡融刚,黄若双,杜荣归,林昌健.氯离子侵蚀下钢筋在混凝土中腐蚀行为的EIS研究[J].物理化学学报,2003,19(1):46-50. 被引量:34
  • 3阎培渝,崔路.腐蚀研究中电流阶跃法的频域分析[J].清华大学学报(自然科学版),1999,39(6):124-127. 被引量:5
  • 4Flis J, Pikering H, Osseo-asare W K. Interpretation of impedance data for reinforcing steel in alkaline solution containing chlorides and acetates[J]. Electrochem. Acta, 1998, 43(12-13): 1921.
  • 5刘晓敏,史志明,林海潮,宋光铃,曹楚南.钢筋在混凝土模拟液中腐蚀行为的EIS特征[J].中国腐蚀与防护学报,1997,17(1):19-24. 被引量:9
  • 6Gonzalez J A, Cobo A, Gonzalez M N, et al. On-site deter- mination of corrosion rate in reinforced concrete structures by use of galvanostatic pulses[J]. Corros. Sci., 2001, 43(4): 611.
  • 7武世翔,朱雅仙,朱锡昶,葛燕,朱秀娟.电脉冲信号暂态响应法评定钢筋腐蚀状态[J].水利水运工程学报,2001(1):55-61. 被引量:3
  • 8Feliu S, Galvan J C, Feliu Jr S, et al. Differences be- tween apparent polarization resistance values obtained in the time and frequency domains[J]. J. Electroanal. Chem., 1995, 381(1-2): 1.
  • 9Feliu S, Gonzalez J A, Andrade C, et al. The determi- nation of the corrosion rate of steel in concrete by a non- stationary method[J]. Corros. Sci., 1986, 26(11): 961.

二级参考文献16

  • 1曹楚南,王佳,林海潮.氯离子对钝态金属电极阻抗频谱的影响[J].中国腐蚀与防护学报,1989,9(4):261-270. 被引量:83
  • 2王佳,曹楚南,林海潮.孔蚀发展期的电极阻抗频谱特征[J].中国腐蚀与防护学报,1989,9(4):271-279. 被引量:60
  • 3[2]Song, G.L. Cement and Concrete Research, 2000, 30(11):1723
  • 4[3]Sagues, A.A.; Kranc, S.C.; Moreno, E.I. Corrosion Science, 1995, 37(7): 1097
  • 5[4]Feliu, V.; Gonzalez, J. A.; Andrade, C.; Feliu, S. Corrosion Science, 1998, 40(6): 975
  • 6[7]Atkins, C. P.; Carter, M. A.; Scantlebury, J.D. Cement and Concrete Research, 2001, 31 (8): 1207
  • 7[9]Monticelli, C.; Frignani, A.; Trabanelli, G. Cement and Concrete Research, 2000, 30(4): 635
  • 8[10]Flis, J.; Picketing, H.W.; Osseo-Asare, K. Electrochimica Acta, 1998, 43(12-13): 1921
  • 9[12]Glass, G. K.; Reddy, B.; Buenfeld, N.R. Corrosion Science, 2000, 42(11): 2013
  • 10[13]Glass, G. K.; Hassanein, A.M.; Buenfeld, N.R. Corrosion, 1998, 54(11): 887

共引文献46

同被引文献98

  • 1于继寿,殷国伟,葛勇,袁杰,张宝生,郑秀华.掺合料对钢筋锈蚀性能的影响[J].武汉理工大学学报,2009,31(2):82-86. 被引量:5
  • 2江毅,严云,Christopher K.Y.Leung.光纤光栅腐蚀传感器[J].光子学报,2006,35(1):96-99. 被引量:20
  • 3丁元力,董泽华,周华林,佘海龙.基于护环技术的混凝土中钢筋腐蚀监测研究[J].中国腐蚀与防护学报,2006,26(5):257-262. 被引量:7
  • 4刘晓敏,史志明,林海潮,宋光铃,曹楚南.钢筋在混凝土模拟液中腐蚀行为的EIS特征[J].中国腐蚀与防护学报,1997,17(1):19-24. 被引量:9
  • 5ASTM C876-91, Standard test method for half-cell potentials of un- coated reinforcing steel in concrete[S]. 1999.
  • 6Elsener B, Andrade C, Gulikers J, et al, Hall-cell potential measure- ments-potential mapping on reinforced concrete structures [J]. Ma- ter.Struct., 2003, 36(7): 461.
  • 7Flis J, Picketing H W, Osseo-Asare K. Interpretation of impedance data for reinforcing steel in alkaline solution containing chlorides and acetates [J]. Electrochim. Acta, 1998, 43(12-13): 1921.
  • 8John P B. The use of permanent corrosion monitoring in new and existing reinforced concrete structures [J]. Cement Concr. Com- posites, 2002, 24:27.
  • 9Yeih W, Huang R. Detection of the corrosion damage in reinforced concrete members by ultrasonic testing [J]. Cement Concr. Res., 1998, 28(7): 1071.
  • 10Erdogdu S, Kondratova I L, Bremner T W. Determination of chlo- ride diffusion coefficient of concrete using open-circuit potential measurements [J]. Cement Concr. Res., 2004, 34(4): 603.

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部