摘要
通过一起实例计算,分析线路阻波器在超短输电线路中的潮流影响。提出在超短输电线路设计时需要特别注意的问题。并针对线路阻波器导致的潮流不平衡,提出解决办法。
Based on a case calculation,this essay analyzes the influence of the wave trapper on the ultra-short transmission line's flow,points out the problems which should be paid special attention to in the design of the ultra-short transmission line,and presents relevant solutions to the unbalanced flow caused by the wave trapper.
出处
《重庆电力高等专科学校学报》
2011年第3期78-80,共3页
Journal of Chongqing Electric Power College
关键词
线路阻波器
超短输电线路
潮流异常
wave trapper
ultra-short transmission line
unbalanced flow