期刊文献+

影响竖直埋管单位孔深换热量的因素分析 被引量:1

Influence Factor Analysis on the Heat Exchange of Unit Vertical Embedded Pipe
下载PDF
导出
摘要 地下换热器是地源热泵的重要组成部分,竖直U型管是最常见的地下换热器形式。运用地热之星,计算和模拟了山东省某地区实际工程地源热泵空调系统。讨论和分析了循环液进出口温度,土壤热物性,换热器结构,地埋管管径对单位孔深换热量的影响,整理分析得出的上述因素对单位孔深换热量的影响,可以作为实际工程优化设计的依据。 The ground heat exchanger is an important component of the Ground source Heat Pump (GSHP) and the U-tube is most commonly used ground heat exchanger. Geo Star is used to calculate and simulate the GSHP air conditioning system of a certain area in Shandong province. Discuss and analyze the effect of the inlet and outlet temperature of the circulating water, thermal physical property of soil, structures of heat exchangers and the size of the buried tubes on the heat exchange of unit hole depth. Through setting and analyzing the factors above how to affect the heat exchange of unit hole depth, can be regarded as the reference of optimization design for practical project.
出处 《制冷与空调(四川)》 2011年第3期315-318,共4页 Refrigeration and Air Conditioning
关键词 地源热泵 地热换热器 单位孔深换热量 软件 GSHP ground heat exchanger heat exchange of unit hole depth software
  • 相关文献

参考文献8

  • 1Zeng Heyi, Diao Nairen, Fang Zhaohong. Heat transfer analysis of boreholes in vertical ground heat exchangers [J]. International Journal of Heat and Mass Transfer, 2003,(46):4467 4481.
  • 2Diao Nairen, Cui P, Fang Zhaohong. The thermal resistance in a borehole of geothermal heat exchangers [C]. Proc.12th International Heat Transfer Conference, 2002:339-343.
  • 3Diao Nairen, Zeng Heyi, Fang Zhaohong. Improvement on modeling of heat transfer in vertical ground heat exchangers[J]. International Journal of HVAC&R Research, 2004.
  • 4Diao Nairen, Li Qingyun, Fang Zhaohong. Heat Transfer in Ground Heat Exchangers with Groundwater Advection[J]. International Journal of Thermal Sciences, 2004, 43 (12):1203-1211.
  • 5Ping Cui, Hongxing Yang, Zhaohong Fang. Heat transfer analysis of ground heat exchangers with inclined boreholes[J]. Applied Thermal Engineering, 2006,(26): 1169-1175.
  • 6崔萍.[D].济南:山东建筑工程学院,2002.
  • 7陈卫翠 李旻 刁乃仁 等.竖直埋管地热换热器的设计和参数分析.中国建设信息,2006,(2):19-23.
  • 8于明志,方肇洪.现场测试地下岩土平均热物性参数方法[J].热能动力工程,2002,17(5):489-492. 被引量:34

二级参考文献8

  • 1[1]SULATISKY M T, GVAN DER KAMP. Ground-source heat pumps in the candian prairies[J].ASHRAE Transactions, 1991,97(1):374-385.
  • 2[2]LARRY M, FETTKETHER. Geothermal system meets space heating requirements[J]. ASHRAE Journal,1992,98(3):43-45.
  • 3[3]CANE R L D, FORGAS D A. Modeling of ground-source heat pump performance[J]. ASHRAE Transaction, 1991,97(1):909-925.
  • 4[4]STEPHEN P, KAVANAUGH. Field tests for ground thermal properities-methods and impact on ground-source heat pump design[J].ASHRAE Transactions, 1992,98(2):607-615.
  • 5[5]BOSE J E. Soil and rock classification for the design of ground-coupled heat pump systems-field manual[R]. Epri CU-6600, Oklahoma: International Ground Source Heat Pumps Association, 1989.
  • 6[6]YU M Z, FANG Z H. The influence of soil freezing on heat transfer of geothermal heat exchangers[A].CSPE-JSPE-ASME,International Conference on Power Engineering[C]. Xi′an:TUP and Springer, 2001.1442-1449.
  • 7[7]KAVANAUGH S P, RAFFERTY K. Ground-source heat pumps: Design of geothermal systems for commercial and institutional buildings [M]. Atalanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, 1997.
  • 8[8]GU YIAN, O′NEAL DENNIS L. Development of an equivalent diameterr expression for vertical U-Tube used in ground-coupled heat pumps[J]. ASHRAE Transactions, 1998,104(2):347-355.

共引文献39

同被引文献7

  • 1徐琳,张旭,张学庆.土壤热源热泵系统节能分析[J].煤气与热力,2006,26(3):42-44. 被引量:3
  • 2方荣生 项立成 李亭寒.太阳能应用技术[M].北京:中国农业机械出版社,1982..
  • 3Ball D A, FISCHER R D, HODGETT D L. Design methods for ground-source heat pumps[ J]. ASHRAE Transactions, 1983,89 (2) :416 - 440.
  • 4WANG Jing-gang, ZHAO Jin, YIN Zhen-Jiang, et al. Hot properties of soil testing and analysis for ground source heat pump [ C ]. International Conference on Challenges in Environmental Science and Computer Engineering, 2010.
  • 5ZHOU Dong-yi, SHI Chu-ping,YUAN Wen-hua. Re- search on the applicability of solar energy-guound source heat pump in different regions of china [ C ]. Second International Conference on Digital Manufactur- ing & Automation ,2011.
  • 6LIU Wen-jie, MIAO Xiao-ping, WANG Jin-sheng, et al. Thermal storage cooling tower for underground commercial building[ C ]. ICSET,2008.
  • 7林小闹,曾冬琪.风机盘管机组选型问题的探讨[J].暖通空调,2011,41(11):59-62. 被引量:15

引证文献1