摘要 眼压增高是青光眼致病原因的主要危险因素,研究眼压检测技术对青光眼的诊治至关重要。利用眼压计测眼压法是目前临床主要采用的眼内压测量方法。文章论述了传统眼压检测技术和最近发展的新型眼压测量技术在临床眼压测量中的应用现状,结合目前市场新的应用需求对今后眼压检测技术的发展进行了展望,为眼压计的研究开发以及临床应用提供参考。 An elevated intraocular pressure(IOP) is the main risk factor of glaucoma progression.Study of available technologies for the precise measurement of IOP is crucial for the diagnosis and treatment of glaucoma.The developments in tonometry from the conventional tonometers to the novel pressure tonometers that are recently presented for clinical use are reviewed.The future development of the technology of IOP measurement is prospected in light of the new market demands.This paper provides a reference for the research,manufacture and clinical application of the tonometer.
出处 《合肥工业大学学报(自然科学版)》 CAS CSCD 北大核心 2011年第7期976-981,共6页 Journal of Hefei University of Technology:Natural Science
基金 安徽省教育厅自然科学基金资助项目(KJ2011Z060KJ2008A146) 安徽省自然科学基金资助项目(11040606M128)
关键词 青光眼 眼内压 眼压测量法 眼压计 glaucoma intraocular pressure(IOP) intraocular pressure measuarment tonometer
  • 相关文献

参考文献2

二级参考文献18

  • 1邹海东,张皙,许迅,柏林.低视力者生活质量量表中文版的研制和信度与效度考评[J].中华眼科杂志,2005,41(3):246-251. 被引量:164
  • 2A. W. Siu, M. C. P. Leung, C. H. To, F. K. W. Siu, J. Z. Ji, and K. F. So, Exp. Eye Res. 75, 401 (2002).
  • 3K. C. Katuri, S. Asrani, and M. K. Ramasubramanian, IEEE Sens. J. 8, 12 (2008).
  • 4G. K. Krieglstein and W. K. Waller, Graefes Arch. Clin. Exp. Ophthal. 194, 11 (1975).
  • 5J. H. Fisher, P. G. Watson, and G. Spaeth, Eye 2, 238 (1988).
  • 6C. Kniestedt and H. E. Kanngiesser, Ophthalmologe 8, 713 (2006).
  • 7E. Perkins, Br. J. Opthalmol. 49, 591 (1965).
  • 8M. Kong, Z. Gao, L. Chen, and X. Li, Chin. Opt. Lett. 6, 377 (2008).
  • 9J. Draeger, "Applanation tonometer" U.S. Patent 005203331A (Apr. 30, 1993).
  • 10S. Asrani, R. Zeimer, J. Wilensky, D. Gieser, S. Vitale, and K. Lindenmuth, J. Glaucoma 9, 134 (2000).

共引文献12

同被引文献35

  • 1练苹,顾欣祖,叶秀兰.正常人瞳孔及瞳孔对光反射的特征[J].中国实用眼科杂志,2005,23(10):1038-1041. 被引量:27
  • 2祝远方,郭文毅.新型非接触式眼压分析仪ORA与Goldmann压平眼压计的比较[J].中国实用眼科杂志,2007,25(5):521-523. 被引量:6
  • 3十合晋一.气体轴承设计、制作与应用[M].韩焕臣译.北京:宇航出版社,1988.
  • 4Kanngiesser H E, Kniestedt C,Robert Y C. Dynamiccontour tonometry: presentation of a new tonometer[J]. Journal of Glaucoma?2005 ,14(5): 344-350.
  • 5Lam A K,Chan R,Lam C H. The validity of a newnoncontact tonometer and its comparison with theGoldmannn tonometer [J]. Optometry and VisionScience,2004,81(8):601-605.
  • 6Pepose J S,Feigenbaum S K,Qazi M A,et al. Changesin corneal biomechanics and intraocular pressurefollowing LASIK using static, dynamic and noncontacttonometry [j]. American Journal of Ophthalmology,2007,143(1):39-47.
  • 7Lam A, Chen D, Chiu R, et al. Comparison of IOPmeasurements between ORA and GAT in normalChinese[J]. Optometry and Vision Science,2007,84(9):909-914.
  • 8Kempf R,Kurita Y,Lida Y,et al. Understanding eyedeformation in non-contact tonometry[C] // Proceedingsof the 28th Annual International Conference of theIEEE Engineering Medicine and Biology Society,August 30-September 3,2006,New York,NY.Piscataway:IEEE Press,2006 ,1:5428-5431.
  • 9Han Y M,Bryanston-Cross P J,Lee W K,et al. Activenon-contact tonometer for glaucoma detection [ J].Optics in Health Care and Biomedical Optics:Diagnostics and Treatment ?2002,4916: 143-150.
  • 10Ogbuehi K C? Almubrad T M. Accuracy and reliabilityof the Keeler Pulsair EasyEye non-contact tonometer[J]. Optometry and Vision Science, 2008? 85( 1 ):61-66.

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部