期刊文献+

正常肝脏和小肝癌多层螺旋CT灌注成像的研究 被引量:1

下载PDF
导出
摘要 CT灌注成像作为一种成熟的功能影像技术对肝脏疾病的诊断具有巨大潜力。通过正常肝脏和小肝癌(及对其跟踪复查)的多层螺旋CT灌注成像,研究其血液动力学改变,取得的成果:①获得了正常肝脏和小肝癌CT灌注成像评价指标;②据此指标证实CT灌注成像对小肝癌的检出早于形态学之前;③揭示了小肝癌病情进展过程中不同时期代谢状态的关注情况。
出处 《医学信息(中旬刊)》 2011年第7期3390-3390,共1页 Medical Information Operations Sciences Fascicule
  • 相关文献

参考文献4

  • 1汤钊猷,余业勤.原发性肝癌.上海[J].上海医科大学出版社,1999:86-122.
  • 2范光明,郭启勇.肝脏CT灌注成像的研究进展[J].中国医学影像技术,2004,20(2):298-301. 被引量:21
  • 3Miles KA, Griffiths MR, Fuentrs MA. standardozed perfusion Value : jniver- sad CT contrast enhancement scale. Radiology ,2001,220:548 -553.
  • 4Van Beers,Leeonte I, Materne R, et al. Hepatic perfvsinn parameters in chro- nic liver disease:dynamic CT mesavrements correatad With disease severity AIR ,2001,176:667 - 673.

二级参考文献21

  • 1[1]Eastwood JD,Lev MH,Azhari T,et al. CT perfusion scanning with deconvolution analysis:pilot study in patients with acute middle cerebral artery stroke [J]. Radiology,2002,222(1):227-236.
  • 2[2]Furukawa M,Kashiwagi S,Matsunaga N,et al. Evaluation of cerebral perfusion parameters measured by perfusion CT in chronic cerebral ischemia: comparison with Xenon CT [J]. J Comput Assist Tomogr,2002,26(2):272-278.
  • 3[3]Miles KA,Heyball MP,Dixon AK,et al. Functional images of hepatic perfusion obtained with dynamic CT [J]. Radiology,1993,188(2):405-411.
  • 4[4]Blomley MJK,Coulden R,Dawson P,et al. Liver perfusion studied with ultrafast CT [J]. J Comput Assist Tomogr,1995,19(3):424-433.
  • 5[5]Materne R,Van Beers BE,Smith AM,et al. Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model [J]. Clin Sci,2000,99(6):517-525.
  • 6[6]Cuenod CA,Leconte I,Siauve N,et al. Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT [J]. Radiology,2001,218(2):556-561.
  • 7[7]Miles KA. Measurement of tissue perfusion by dynamic computed tomography [J].Br J Radiol,1991,64(761):409-412.
  • 8[8]Hindmarsh T. Elimination of water-soluble contrast media from the subarachnoid space: investigation with computed tomography [J]. Acta Radiol,1975,346(Suppl):45-49.
  • 9[9]Axel L.Cerebral blood flow determination by rapid-sequence computed tomography [J]. Radiology,1980,137(3):679-686.
  • 10[10]Bader TR,Herneth AM,Blaicher W,et al. Hepatic perfusion after liver transplantation: noninvasive measurement with dynamic single-section CT [J]. Radiology,1998,209(1):129-134.