期刊文献+

白内障患者功能性视力的研究现状 被引量:4

Research status of functional vision in cataract patients
下载PDF
导出
摘要 功能性视力检查包括连续性功能视力、眼内散射光、波前像差、点扩散函数、调制传递函数、对比敏感度、眩光敏感度、双眼视觉功能等,作为一种全面评估视觉质量的方法,广泛应用于早期视力尚未受损但有主观视觉损害的白内障患者,也可用于客观评价屈光性、老视矫正性白内障手术后患者是否能看得见,看得清晰,看得舒服。 Functional vision examination comprises of continuous functional visual acuity, intraocular straylight, wavefront aberration, point spread function, modulation transfer function, contrast sensitivity, glare sensitivity, binocular visual function, etc. Functional vision examination is a comprehensive and useful tool, which is widely used in evaluating cataract patients whose visual acuity is good at early stage but objective quality of vision is bad, also in evaluating whether the patients could not only see but also see clearly and comfortably after refractive and presbyopia-correcting cataract surgery.
出处 《国际眼科杂志》 CAS 2011年第8期1385-1388,共4页 International Eye Science
基金 中国辽宁省教育厅高等学校优秀人才支持计划项目(No.2009R53)~~
关键词 白内障 视觉质量 功能性视力 眼内散射光 cataract visual quality functional vision intraocular straylight
  • 相关文献

参考文献47

  • 1Colenbrander A. Assessment of functional vision and its rehabilitation. Acta Ophtbalmol 2010 ;88 ( 2 ) : 163-173.
  • 2Kaido M, Dogru M, Yamada M, et al . Functional visual acuity in Stevens-Johnson syndrome.Am J Ophthalmol 2006 ;142(6) :917-922.
  • 3Goto E, Yagi Y, Matsumoto Y, et al . Impaired functional visual acuity of dry eye patients.Am J Ophthalmol 2002 ;133 (2) : 181-186.
  • 4Ishida R, Kojima T, Dogru M, et al . The application of a new continuous functional visual acuity measurement system in dry eye syndromes. Am J Ophthalmol 2005 ; 139 ( 2 ) :253-258.
  • 5Tanaka M, Takano Y, Dogru M, et al . Effect of preoperative tear function on early functional visual acuity after laser in situ keratomileusis. J Cataract Refract Surg 2004 ;30( 11 ) :2311-2315.
  • 6哈文静,徐惠芳,邹文青,李静,顾青,贾沁.LASIK术后泪液稳定性及功能性视力的研究[J].国际眼科杂志,2009,9(11):2118-2120. 被引量:11
  • 7刘祖国,罗丽辉,张振平,程冰,郑丹莹,陈伟蓉,林振德,杨文辉,刘奕志,张梅,肖启国,陈家祺.超声乳化白内障吸除术后泪膜的变化[J].中华眼科杂志,2002,38(5):274-277. 被引量:197
  • 8Van Den Berg TJ, Van Rijn LJ, Michael R, et al . Straylight effects with aging and lens extraction. Am J Ophthamo 2007 ; 144 ( 3 ) : 358-363.
  • 9van Rijn LI, Nischler C, Michael R, et al. Prevalence of impairment of visual function in European drivers.Acta Ophthalmol 2011 ;89(2) :124-131.
  • 10Rozema JJ, Van den Berg TJTP, Tassignon MJ. Retinal Straylight as a Function of Age and Ocular Biometry in Healthy Eyes.Invest Opbthalmol Vis Sci 2010;51 (5) :2795-2799.

二级参考文献24

  • 1张汉承 周祖濂.泪膜的生理和病理.泪腺病学[M].北京:金盾出版社,1992.91.
  • 2Melki SA, Azar DT. LASIK complications: etiology, management, and prevention. Surv Ophthalmol 2001, 46(2):95-116.
  • 3Hovanesian JA, Shah SS, Maloney RK. Symptoms of dry eye and recurrent erosion syndrome after refractive surgery. J Cataract Refract Surg 2001,27(4):577-584.
  • 4Goto E, Yagi Y, Matsumoto Y, et al. Impaired functional visual acuity of dry eye patients. Am J Ophthalmol 2002,133(2):181-186.
  • 5Linna TU, Vesaluoma MH, Perez-Santonja JJ, et al. Effect of myopic LASIK on corneal sensitivity and morphology of subbasal nerves. Invest Ophthalmol Vis Sci 2000,41(2):393-397.
  • 6Lee BH, McLaren JW, Erie JC, et al. Reinnervation in the cornea after LASIK. Invest Ophthalmol Vis Sci 2002,43(12):3660-3664.
  • 7Vilarrodona L,Barrett GD,Johnson B.High order aberrations in pseudophakia with different intraoeular lenses.J Cataract Refract Surg,2004,30:571-575.
  • 8Jack TH,Patricia AP,Gabor K,et al.A new intraocular lens design to reduce spherical aberration of pserdophakic eyes.J Refract Surg,2002,18:683-691.
  • 9Dick HB.Recent developments in aspheric intraocular lenses.Curr Opin Ophthalmol,2009,20:25-32.
  • 10Artal P,Berrio E,Guirao A,et al.Contribution of the cornea and internal surfaces to the change of ocular aberrations with age.J Opt Soc Am A Opt Image Sci Vis,2002,19:137-143.

共引文献223

同被引文献77

  • 1毛崇溶,吕帆,赵云娥.白内障早期患者术前及术后的眩光测试[J].眼科研究,2003,21(3):302-304. 被引量:4
  • 2田润,唐罗生,王玲,陈百华,杨辉,黄娟.OCT检测视网膜神经纤维层厚度与视盘大小的相关性研究[J].眼科研究,2007,25(7):540-543. 被引量:13
  • 3李镒冲,李晓松.两种测量方法定量测量结果的一致性评价[J].现代预防医学,2007,34(17):3263-3266. 被引量:154
  • 4Cheng X, Thibos LN, Bradley A. Estimating visual quality from wavefront aberration measurements. J Refract Surg, 2003, 19: 579-584.
  • 5Diaz-Douton F, Benito A, Pujol J, et al. Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a dou- ble-pass instrument. Invest Ophthalmol Vis Sci, 2006, 47: 1710-1716.
  • 6Saad A, Saab M, Gatinel D. Repeatability of measurements with a double-pass system. J Cataract Refract Surg, 2010, 36: 28-33.
  • 7Benito A, Perez GM, Mirabet S, et al. Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes. J Cataract Refract Surg, 2011, 37: 1481-1487.
  • 8Artal P, Benito A, P6rez GM, et al. An objective scatter index based on double-pass retinal images of a point source to classify cataracts. PLoS ONE, 20310, 6: e16823.
  • 9Cuell JL, Pujol J, Arjona M, et al. Optical quality analysis system: instrument for objective clinical evaluation of ocular optical qual- ity. J Cataract Refract Surg, 2004, 30: 1598-1599.
  • 10Vilaseca M, Peris E, Pujol J, et al. Intra- and intersession repeata-bility of double-pass instrument. Optom Vis Sci, 2010, 87: 675-681.

引证文献4

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部