摘要 目的:比较Orbscan眼前节分析系统与光学相干生物测量仪IOLMaster测量角膜曲率的差异。方法:我院2010-09/12屈光手术前近视患者68例135眼,排除近期隐形眼镜配戴史、严重干眼患者、曾经进行过角膜手术者以及其他眼部器质性病变者,其中男46例91眼,女22例44眼,同时用两种方法测量角膜曲率,进行临床比较。结果:Orbscan眼前节分析系统、IOLMaster两种仪器测量角膜曲率结果分别为43.4637±1.4188,43.6952±1.3676D。两组间比较,差异无统计学意义(P>0.05)。结论:Orbscan眼前节分析系统与IOLMaster对近视患者角膜曲率检查结果无统计学差异。IOLMaster用于屈光手术术前角膜曲率检查评估有一定价值。 AIM: To analyze keratometric readings obtained from Orbscan topography system and IOLMaster in myopia patients. METHODS:The corneal curvature were measured with Orbscan topography system and IOLMaster respectively in 68 cases(135 eyes) subjects aged 18-41 years old. There were 46 male(91 eyes) and 22 female(44 eyes)subjects. The results were compared. RESULTS:The average corneal curvature measured by Orbscan topography system and IOLMaster were 43. 4637 ± 1. 4188 and 43. 6952 ± 1. 3676D. The measurement obtained from Orbscan topography system was lower than that from IOLMaster, There is no statistical difference between the two methods. CONCLUSION. Corneal curvature abtained from IOLMaster showed no significant difference than that from Orbscan system. It is a clinically useful tool in eveluating corneal surface curvature.
机构地区 安阳眼科医院
出处 《国际眼科杂志》 CAS 2011年第8期1479-1480,共2页 International Eye Science
关键词 ORBSCAN系统 光学相干生物测量仪 角膜曲率测量 对比研究 Orbscan topography system IOLMaster keratometry comparative study
  • 相关文献

参考文献8

二级参考文献54

  • 1张亚丽,赵云娥,王勤美.光学相干生物测量仪测量人工晶状体度数精确性的评价[J].眼视光学杂志,2005,7(1):41-43. 被引量:11
  • 2Jacobs JM,Taravella MJ.Incidence of intraoperative flap complications in laser in situ keratomileusis[J].J Cataract Refract Surg,2002,28(1):23-28.
  • 3Gimbel HV,Penno EEA,Van Westenbrugge JA,et al.Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases[J].Ophthalmology,1998,105(10):1839-1847.
  • 4Rabinowitz YS.Keratoconus[J].Surv Ophthalmol,1998,42(4):297-319.
  • 5Waheed S,Krueger RR.Steep,flat and irregular corneas in LASIK[EB/OL].Review of Ophthal Vol:10 No:02 Issue:2/15/03.http://www.revophth.com.
  • 6Melk SA,Azar DT.LASIK complications:etiology,management,and prevention[J].Surv Ophthalmol,2001,46(2):95-116.
  • 7O'rahilly R.The prental development of the human eye[J].Exp Eye Res,1975,21(2):93-112.
  • 8Leung AT,Rao SK,Cheng A,et al.Pathogenesis and management of LASIK flap buttonhole[J].J Cataract Refract Surg,2000,26(3):358-362.
  • 9Farah SG,Azar DT,Gurdal C,et al.Laser in siu keratomileusis:literature review of a developing technique[J].J Cataract Refract Surg,1998,24(7):989-1006.
  • 10Sarkisian KA,Petrov AA.Experience with the Nidek MK-2000 microkeratome in 1220 cases[J].J Refract Surg,2001,17(2 Suppl):S252-254.

共引文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部