摘要
通过对空压机励磁柜模块几次损坏的原因分析,排除了设各在安装中存在的故障隐患,确保了设备的连续稳定运行。
On the basis of reason analysis of damage of several times of mod- ules in the magnetizing tank of an air compressor hidden troubles of failure in in-stallation of devices are eliminated. Thus, continuous and stable operation of the devices is guaranted.
出处
《冶金动力》
1999年第6期44-45,共2页
Metallurgical Power