摘要
背景:近年来,注塑微波聚合技术在临床应用越来越多,其制作义齿精度方面的研究在国内鲜见报道。目的:观察注塑微波方法对树脂基托义齿精度的影响。方法:用注塑微波法和水浴法分别制作上颌全口义齿各10个,然后在上颌第二磨牙远中部位切断义齿基托与标准模型,用数字显微镜测量上颌全口义齿基托组织面与标准模型之间共5个部位的间隙。结果与结论:注塑微波法制作的义齿5个部位的精度为:(200±32),(76±13),(69±15),(81±16),(187±27)μm,水浴法制作的义齿5个部位的精度为:(243±50),(100±26),(96±30),(109±32),(213±28)μm,两种方法在相同点处差异有显著性意义(P<0.05)。提示在精度方面,注塑微波法制作的义齿优于水浴法,并且注塑微波法聚合时间较水浴法明显缩短。
BACKGROUND:In recent years,clinical applications of injection microwave polymerization have been on the rise.However,reports on its production of denture precision are rarely seen in China and the accuracy needs further verification.OBJECTIVE:To evaluate the effect of injection microwave polymerization on accuracy of denture base resin.METHODS:The study was to compare the difference of denture base resin cured by injection microwave polymerization and water-bath heat polymerization.The dimensional accuracy between the posterior border of upper complete denture and standardized cast at five different positions was measured by digital microscope.RESULTS AND CONCLUSION:The five posterior border gaps between the upper complete denture and standardized cast were(200±32) μm,(76±13) μm,(69±15) μm,(81±16) μm,(187±27) μm by the injection microwave polymerization,and(243±50) μm,(100±26) μm,(96±30) μm,(109±32) μm,(213±28) μm by the water-bath heat polymerization.There was significant difference between the two groups(P 0.05).Injection microwave polymerization is better than water-bath heat polymerization on accuracy of denture base resin,and the time that injection microwave polymerization takes is shorter than that by water-bath heat polymerization.
出处
《中国组织工程研究与临床康复》
CAS
CSCD
北大核心
2011年第25期4643-4646,共4页
Journal of Clinical Rehabilitative Tissue Engineering Research
基金
深圳市科技计划项目(医疗卫生类)(201003286)
课题名称"注塑微波方法对树脂基托义齿精度和物理性能的影响研究"~~