期刊文献+

Quantitative Analysis of Holmium Ion by a Ho^3+ Ion-Selective Sensor Based on a Symmetric Thio-Schiff's Base

Quantitative Analysis of Holmium Ion by a Ho^3+ Ion-Selective Sensor Based on a Symmetric Thio-Schiff's Base
原文传递
导出
摘要 A poly(vinyl chloride) (PVC) membrane sensor for holmium ions was fabricated based on N-[(Z)-l-(2-thienyl)- methylidene]-N-[4-(4-{[(Z)-l-(2-thienyl)methylidene]amino} phenoxy)phenyl] amine (TPA) as a new ion carrier, acetophenon (AP) as plasticizing solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. The electrode shows a good selectivity towards Ho^3+ ions respect to other inorganic cations, including alkali, alka- line earth, transition and heavy metal ions. The constructed sensor displays a Nernstian behavior (19.5±0.3 mV/decade) over the concentration range of 1.0× 10^-6 to 1.0 ×10^- 2 mol·L^-1 with the detection limit of the electrode being 4.6)〈 10-7 mol·L^-1 and very short response time (ca. 5 s). It has a useful working pH range of 3.2-9.8 for at least 8 weeks. The electrode was successfully applied as an indicator electrode for the potentiometric titration of a Ho^3+ solution with EDTA and holmium determination in some alloys. The proposed sensor accuracy was studied by the determination of Ho^3+ in mixtures of three different ions. A poly(vinyl chloride) (PVC) membrane sensor for holmium ions was fabricated based on N-[(Z)-l-(2-thienyl)- methylidene]-N-[4-(4-{[(Z)-l-(2-thienyl)methylidene]amino} phenoxy)phenyl] amine (TPA) as a new ion carrier, acetophenon (AP) as plasticizing solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. The electrode shows a good selectivity towards Ho^3+ ions respect to other inorganic cations, including alkali, alka- line earth, transition and heavy metal ions. The constructed sensor displays a Nernstian behavior (19.5±0.3 mV/decade) over the concentration range of 1.0× 10^-6 to 1.0 ×10^- 2 mol·L^-1 with the detection limit of the electrode being 4.6)〈 10-7 mol·L^-1 and very short response time (ca. 5 s). It has a useful working pH range of 3.2-9.8 for at least 8 weeks. The electrode was successfully applied as an indicator electrode for the potentiometric titration of a Ho^3+ solution with EDTA and holmium determination in some alloys. The proposed sensor accuracy was studied by the determination of Ho^3+ in mixtures of three different ions.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2011年第7期1523-1528,共6页 中国化学(英文版)
关键词 holmium ion PVC membrane SENSOR POTENTIOMETRY Schiffs base ion-selective electrode holmium ion, PVC membrane, sensor, potentiometry, Schiffs base, ion-selective electrode
  • 相关文献

参考文献45

  • 1Faridbod, F.; Ganjali, M. R.; Dinarvand, R.; Norouzi, P. Comb. Chem. High Throughput Screening 2007, 10, 527.
  • 2Zamani, H. A.; Hamed-Mosavian, M. T.; Aminzadeh, E.; Ganjali, M. R.; Ghaemy, M.; Behmadi, H.; Faridbod, F. Desalination 2010, 250, 56.
  • 3Zamani, H. A.; Ganjali, M. R.; Norouzi, P.; Adib, M.; Aceedy, M. Anal. Sci. 2006, 22, 943.
  • 4Greenwood, N. N.; Earnshaw, A. Chemistry of the Elements, Pergamon, New York, 1984.
  • 5Ganjali, M. R.; Memari, Z.; Faridbod, E; Dinarvand, R.; Norouzi, P. Electroanalysis 2008, 20, 2663.
  • 6Ganjali, M. R.; Faridbod, E; Norouzi, P.; Adib, M. Sens. Actuators B 2006, 120, 119.
  • 7Ganjali, M. R.; Norouzi, P.; Atrian, A.; Faridbod, E; Megh-dadi, S.; Giahi, M. Mater Sci. Eng. C 2009, 29, 205.
  • 8Ganjali, M. R.; Tavakoli, M.; Faridbod, E; Riahi, S.; No- rouzi, P.; Salavati-Niassari, M. Int. J. Electrochem. Sci. 2008, 3, 1559.
  • 9Kabalin, J.; Gilling, P.; Fraundorfer, M. J. Clin. Laser Med. Surg. 1998, 16, 21.
  • 10Sastri, V. S.; Bunzli, J. C. G.; Rao, V. R.; Rayudu, G. V. S.; Perumareddi, J. R. Modern Aspects of Rare Earths and Their Complexes, Elsevier Publication, Amsterdam, 2003.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部