期刊文献+

流动注射化学发光法测定肾上腺素 被引量:1

CHEMILUMINESCENCE DETERMINATION OF EPINEPHRINE BY FLOW INJECTION
下载PDF
导出
摘要 作者采用流动注射技术,对肾上腺素-高锰酸钾体系的化学发光行为,影响化学发光强度的诸因素进行了探讨,建立了化学发光法测定肾上腺素的新方法。方法的检出限为6×10-8g/ml,线性范围为1.0×10-7-1.0×10-5g/ml。对4.0×10-6g/ml肾上腺素进行11次平行测定,得方法的相对标准偏差为1.6%。 A new flow injection chemiluminescence method for the determination of epinephrine wasstudied. It is based on the chemiluminescence reaction of epinephrine-KMnO4. The main factors affecting the determination were investigated. Under optimum conditions, the linear range for the deter mination of epinephrine is 1.0×10-1.0×10-5g/ml, the maximun detrmination is 6×10-7g/ml, the relative standard deriation is 1.6% for 11 measurements to 4.0×10-6g/ml epinephrinestandard solution. This method has been applied to the determination of epinephrine in medicine andtheir results are in good agreement with standards method.
作者 李丽清
出处 《山东农业大学学报(自然科学版)》 CSCD 1999年第4期377-380,共4页 Journal of Shandong Agricultural University:Natural Science Edition
关键词 肾上腺素 化学发光 流动注射技术 epinephrine chemiluminescence flow injection technique
  • 相关文献

参考文献4

  • 1中华人民共和国药典委员会,中国药典.2,1995年,380页
  • 2杨仲元,药物分析杂志,1988年,8卷,4期,207页
  • 3商振华,分析化学,1986年,14卷,10期,770页
  • 4沈同,生物化学,1986年,588页

同被引文献8