期刊文献+

放射治疗楔形照射野应用中应特别注意的几个问题 被引量:2

Some Special Problems about the Usement of Wedge Field in Radiation Therapy
下载PDF
导出
摘要 根据作者多年的工作实践,详细说明了楔形照射野应用中应特别注意的几个问题,确保楔形照射野剂量计算精度达到WHO有关放射治疗质量保证和质量控制的要求。 This article presents and discusses some special problems about the use of wedge field in radiation therapy according to the practice of the author.Thus we attain the rules of quality assurance in radiotherapy by WHO.
出处 《中国医疗器械杂志》 CAS 2011年第4期298-300,共3页 Chinese Journal of Medical Instrumentation
关键词 放射治疗 质量保证 楔形板 楔形因素 Hu Jie, Tao Jianmin, Zhang Ying, Zhang Ying (Dept. of Chemo Radio therapy, Tenth People's Hospital affiliated to Tongji University, Shanghai, 200072, China)
  • 相关文献

参考文献6

二级参考文献17

  • 1程建凡 顾横乐 吕长兴等.动态楔形板的间接验证.中国临床医学实践杂志,2005,4(4):319-320.
  • 2Vander Z W, Welleweerd J. A monte carlo study on internal wedges using BEAM [ J ]. Medical Physics, 2002,29(5) :876 - 885.
  • 3复旦大学,原子核物理实验方法,1981年,58页
  • 4胡逸民,肿瘤放射物理学,1999年,187页
  • 5WHO.Quality assurance in radiotherapy.Geneva[S],1988.28-29
  • 6Ghee M C, Chu P, Leszczynski T, et al. The Siemens virtual wedge[J]. Phys Med Biol, 2003,48(12) : 1785-1794.
  • 7van Santvoort J. Dosimetric evaluation of the Siemens Virtual Wedge[J]. Phys Med Biol,1998,43(9) :2651-2663.
  • 8Popescu A,Lai K,Singer K,et al. Wedge factor dependence with depth,field size, and nominal distance-A general computational rule[J]. Med Phys,1999,26(4):541-549.
  • 9Zhu X R, Gillin M T, Jursinic P A, et al. Comparison of dosimetric characteristics of Siemens virtual and physical wedges[J]. Med Phys,2001,28(2) :174-177.
  • 10Zhu X R, Gillin M T, Ehlers K, et al. Dependence of virtual wedge factor on dose calibration and monitor units[J]. Med Phys, 2001,28(2):174-177.

共引文献24

同被引文献20

  • 1雒书朋,王丽玲.电动楔形板的楔形因子计算方法[J].医疗卫生装备,2006,27(6):54-54. 被引量:1
  • 2单国平 严英师 等.楔形板对加速器高能X射线影响的分析[J].中华放射肿瘤学杂志,1999,8(4):242-242.
  • 3邓春涟.物理楔形板及其临床应用[J].南海医学,2007,18(11):179-181.
  • 4ZHU X R,Gillin M T,Jursinic P A,et al. Comparison of dosimetric characteristics of Siemens VW and physical wedges[J]. Medical Phy- sics,2007,27(10) :2 267-2 277.
  • 5IAEA 398 2000 Absorbed dose determination in eeternal beam ra- diotherapy:an international code of practice for dosimetry based on standards of absorbed dose to water[S].
  • 6IEC 977 1989 Medical electrical equipment-medical electron ac- celerators in the range 1 MeV to 50 1VIeV : guidelines for performance characteristics[S].
  • 7Varatharaj C, Ravikumar M,Sathiyan S,et ol. Variation Of beam cha- racteristics between three different wedges from adual-energy accel- erator[J]. Journal of Medical Physics, 2011,36(3 ) : 133-137.
  • 8LI Z ,Klein E E. Surface and peripheral doses of dynamic and physi- cal wedges[J]. International Journal Radiation Oncology,Biology, Physic, 1997,37 (4) : 921-925.
  • 9陆军,张秀春,吴君心,邱素芳,潘建基.应用Mapcheck验证西门子加速器虚拟楔形板物理参数的研究[J].中华肿瘤防治杂志,2008,15(14):1100-1102. 被引量:9
  • 10DONG Xiaoqing,LUO Wenyun,YUE Kun,WANG Chuanshan,ZHOU Shiqing,PAN Fuxing,WANG Enmin,WANG Chaozhuang.Monte carlo study on 6 MV photon beams of a CyberKnife stereotactic radiosurgery system[J].Nuclear Science and Techniques,2010,21(1):16-19. 被引量:4

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部