期刊文献+

Solid Phase Extraction and Determination of Nickel in Water Samples by Using Novel Thiol-Containing Sulfonamide Polymeric Resin and Atomic Absorption Spectrophotometer

Solid Phase Extraction and Determination of Nickel in WaterSamples by Using Novel Thiol-Containing SulfonamidePolymeric Resin and Atomic Absorption Spectrophotometer
下载PDF
导出
摘要 Interest in preconcentration techniques for the determination of metals at ultratrace levels still continues increasingly because of some disadvantages of flameless atomic absorption spectrometry as well as the high costs of other sensitive methods in compared to flame atomic absorption spectrometry.In this study,thiol-containing sulfonamide resin was synthesized,characterized and applied as a new sorption material for solid phase extraction of nickel in drinking water samples.After preconcentration procedure,flame atomic absorption spectrometry was used for determinations.Optimum parameters were found to be pH=3.2,contact time=20 min and eluate volume=3 mL.The limit of detection was found to be 0.75 ng·mL-1.The synthesized resin exhibits the superiority in compared to the other adsorption reagents because of the fact that there is no necessity of any complexing reagent,high sorption capacity as well as the relatively fast extraction rate.The Ni concentrations in the studied 21 kind of water samples were found to be in the range of BDL-4.0 ng·mL-1. Interest in preconcentration techniques for the determination of metals at ultratrace levels still continues increasingly because of some disadvantages of flameless atomic absorption spectrometry as well as the high costs of other sensitive methods in compared to flame atomic absorption spectrometry.In this study,thiol-containing sulfonamide resin was synthesized,characterized and applied as a new sorption material for solid phase extraction of nickel in drinking water samples.After preconcentration procedure,flame atomic absorption spectrometry was used for determinations.Optimum parameters were found to be pH=3.2,contact time=20 min and eluate volume=3 mL.The limit of detection was found to be 0.75 ng·mL-1.The synthesized resin exhibits the superiority in compared to the other adsorption reagents because of the fact that there is no necessity of any complexing reagent,high sorption capacity as well as the relatively fast extraction rate.The Ni concentrations in the studied 21 kind of water samples were found to be in the range of BDL-4.0 ng·mL^-1.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2011年第8期2243-2248,共6页 Spectroscopy and Spectral Analysis
关键词 Spectroscopy Extraction NICKEL PRECONCENTRATION Atomic absorption Spectroscopy Extraction Nickel Preconcentration Atomic absorption
  • 相关文献

参考文献34

  • 1Yaman M. Curr. Me& Chem., 2006, 13(21): 2513.
  • 2SI No:439, 2000. The European Communities (Drinking Water) Regulations, Dublin, Ireland.
  • 3Ministry of Health, 2005. Insani tuketim amacli sular hakkinda yonetmelik (inTurkish). Resmi Gazete, 25730, Ankara, Turkey.
  • 4WHO (2005) Nickel in Drinking-Water. Background Document for Development of WHO Guidelines for Drinking-Water Quality. Gene va, World Health Organization(WHO/SDE/WSH/05. 08/55).
  • 5Cempel M Nikel, Nickel G. Polish J. Environ. Stud. , 2006, 15(3): 375.
  • 6Sekhar C K, Chary S N. Acta Chirm Stov. , 2003, 50: 409.
  • 7Yaman M. Spectrosc. Lett., 2001, 34(6): 763.
  • 8Karve M, Rajgor R V. J. Hazard Mater. , 2009, 166: 576.
  • 9Pourreza N, Zolgharnein J, Kiasat A R, et al. Talanta, 2010, 81: 773.
  • 10Barroso M F, Ramos S, Oliva-Teles M T, et al. Food Add. Contam. Part B, 2009, 2(2), 121.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部