摘要 目的建立对乙酰氨基酚软胶囊有关物质的高效液相色谱测定方法。方法采用Agilent XDB-C18(150 mm×4.6 mm,5μm)色谱柱,甲醇-水-磷酸(20∶80∶0.1)为流动相,流速1.0 mL.min-1,检测波长为272 nm。结果对氨基酚最低检出限为1.25 ng.mL-1,对乙酰氨基酚与对氨基酚及其他有关物质达到基线分离。结论本方法简便、准确、专属性高,可用于本制剂的有关物质控制。 Objective To establish an HPLC method for the determination of related substances for Paracetamol Soft Capsules.Methods The chromatographic analysis was performed on Agilent XDB-C18(150 mm×4.6 mm,5 μm)column.The mobile phase was methanol-water-phosphoric acid(20∶80∶0.1).The flow rate was 1.0 mL·min-1.The detection wavelength was 272 nm.Results The lowest detection limit of p-aminophenol was 1.25 ng·mL-1(S/N=3).P-aminophenol and its related substances were well isolated with paracetamol.Conclusion The method was simple,accurate,specific and can be used for the quality control of the preparation.
作者 李东 李存福
出处 《齐鲁药事》 2011年第7期394-396,共3页 qilu pharmaceutical affairs
关键词 对乙酰氨基酚软胶囊 高效液相色谱法 对氨基酚 有关物质 Paracetamol Soft Capsules HPLC P-aminophenol Related substances