摘要 介绍了国内外变压器油腐蚀性硫的几种检测方法,对这些试验方法的适用范围、试验条件等进行了对比,考察目前最适合检测变压器油腐蚀性硫的方法。选用性质不同的变压器油基础油和成品油,分别采用铜片法(SH/T0304—1999、ASTM D1275—2006 B)、银片法(SH/T0804—2007)和裹绝缘纸铜线法(IEC62535—2008)在实验室进行腐蚀性硫的检测和对比。结果表明,IEC62535—2008方法是目前检测变压器油是否存在腐蚀性硫倾向的最佳方法。 Several test methods home and abroad for detecting corrosive sulfur in electric insulating oils were introduced and compared from the aspects of applied scope and test conditions,in order to se lect an optimum test method for detecting corrosive sulfur in transformer oils. Meanwhile, the corrosive sulfur in various transformer base oils and products were tested by copper sheet method(SH/T0304-- 1999 andASTMD1275--2006B),silver stri Ptest(SH/T0804 2007)and copper wire wrapped with insulation paper test(IEC62535 2008). Test results showed that IEC62535--2008 was the most suitable method to detect the tendency of existing corrosive sulfur in transformer oils.
出处 《石油炼制与化工》 CAS CSCD 北大核心 2011年第8期88-92,共5页 Petroleum Processing and Petrochemicals
关键词 腐蚀性硫 电气绝缘油 变压器油 corrosive sulfur electric insulating oil transformer oil
  • 相关文献

同被引文献52

  • 1熊良铨,吕贞,刘亚娟,彭瑜.溶剂萃取脱除橡胶油中多环芳烃试验探讨[J].润滑油,2011,26(1):56-60. 被引量:26
  • 2刘枫林,徐魏.石蜡基和环烷基变压器油的性能比较[J].变压器,2004,41(7):27-30. 被引量:36
  • 3马书杰,张玲俊,杨俊杰,宫卫军,昝斌.高压加氢基础油为什么不适于生产变压器油[J].变压器,2006,43(6):17-22. 被引量:7
  • 4Sundara R J, Naidu C J, Dwarakanath K. Influence of Metal Passivator on the Corrosion of Copper Conductors due to Sulphcr in Oil[C]//International Symposium on Electrical Insulating Matcrials,IEEE,2008:487-490.
  • 5Faheem A K, Sundara R J, Ansari M Z A, ct al. An Experimental Study on the Effects of DBDS in Transformer Oil of Power Transformers[C]//2012 International Conference on Advances in Power Conversion and Energy Technologies,IEEE,2012:1-4.
  • 6Schaut A, Autru S, Rop A D, et al. Effects of Irgamet 30 as Additive in Transformer Oil[J]//IEEE Transactions on Dielectrics and Electrical Insulation,2012,19(l):175-180.
  • 7Wiklund P, Levin M, Pahlavanpour B. Copper Dissolution and Metal Passivators in Insulating Oil[J]. IEEE Electrical Insulation Magazine,2007,23(4):7-14.
  • 8Kawarai H, Fujita Y, Tanimura J, et al. Role of Dissolved Copper and Oxygen on Copper Sulfide Generation in Insu- lating Oil[J]. IEEE Transactions on Dielectrics and Electri- cal Insulation,2009,16(5): 1430-1435.
  • 9Malna R, Tumiatt V, Scatiggio F, et al. Transformers Sur- veillance Following Corrosive Sulfur Remedial Procedures [J]. IEEE Transactions on Power Delivery,2011,26(4):2391- 2397.
  • 10Maina R, Tumiatti V, Pompili M, et al. Corrosive Sulfur Ef- fects in Transformer Oils and Remedial Procedures[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2009,16 (6):1655-1663.