摘要
在分析有机热载体炉常见事故的基础上,建立了有机热载体锅炉房火灾危险度分析数学模型。根据工程实际,计算出其火灾危险度计算。计算结果表明采用安全对策措施后,能有效的降低车间的火灾危险性等级。研究结果用于指导有机热载体锅炉房消防安全管理水。
Based on the accident analysis of organic heat carrier boiler, a mathematical model of organic heat carder boiler room fire hazard degree analysis was established. Quantitative analysises of fire hazard degree were achieved on the engineering practice. When the safety countermeasures were used, the fire hazard degree was reduced. The results of the study can be used as reference in the fire safety management to organic heat carrier boiler room.
出处
《广州化工》
CAS
2011年第14期189-191,共3页
GuangZhou Chemical Industry
关键词
有机热载体炉
火灾危险度分析
安全对策措施
消防安全管理
organic heat carrier boiler
fire hazard degree analysis
safety countermeasures
fire safety management