期刊文献+

可控串联补偿电容器的过电压保护 被引量:3

Overvoltage Protection of Thyristor Controlled Series Capacitors
下载PDF
导出
摘要 以补偿度取36% (其中24% 不可控、12% 可控)的伊敏- 冯屯500 kV 超高压输电系统为例,研究了以电容器电压为同步信号时可控串联补偿(TCSC)系统的内、外部故障、重合闸、电容重投时的过电压问题.提出了采用常规串补和可控串补相结合的补偿方案时TCSC装置过电压保护的参数整定原则:即以重合闸情况确定可控串补模块中氧化锌非线性电阻(MOV)的整定参数,以外部故障确定固定串补模块中MOV 的整定参数,最后以内部故障较核MOV 的能量容量.讨论了重合闸和电容器重投时可采取的控制策略. Based on the Yimin Fengtun 500 kV EHV transmission lines in which the compensation units consist of fixed series capacitors(FSC,24%) and thyristor controlled series capacitors(TCSC,12%), this paper studied overvoltages on TCSC due to short circuit fault, breaker reclosing, and reinsertion of series capacitors. It gave a rule for parameter settings of protective system of TCSC: the energy setting of metal oxide varistor(MOV) for TCSC should be based upon the energy absorbed in the case of breaker reclosing, while that of MOV for FSC is determined by external line section faults, then the capacities of MOV are checked by internal line section faults. For the sake of successful breaker reclosing and reinsertion of capacitors, a simple but effectual control strategy was put forward.
出处 《上海交通大学学报》 EI CAS CSCD 北大核心 1999年第12期1476-1481,共6页 Journal of Shanghai Jiaotong University
基金 国家自然科学基金
关键词 可控串联补偿 过电压保护 高压输电线路 电容器 transmission lines thyristor controlled series capacitors(TCSC) overvoltages protection metal oxide varistor(MOV)
  • 相关文献

参考文献12

二级参考文献10

  • 1翟耀希,陈亚伦.伊敏—大庆500kV系统串联补偿方案研究[J].电网技术,1994,18(5):49-53. 被引量:7
  • 2王秉钧,金属氧化物避雷器,1993年
  • 3陈志清,氧化锌压敏瓷及其在电力系统中的应用,1992年
  • 4李永庄,电力系统电磁暂态计算理论(译),1991年
  • 5团体著者,串联电容补偿装置在电力系统中的应用,1977年
  • 6林集明,电网技术,1997年,21卷,7期
  • 7团体著者,伊冯500kV线路可控串补电磁暂态分析与绝缘配合,1997年
  • 8团体著者,伊敏—冯屯500kV可控串补系统分析——常规部分及可控部分(阶段报告),1996年
  • 9林集明,电网技术,1996年,20卷,10期
  • 10团体著者,美国可控串补技术考察报告,1995年