基于Geant4的γ-CT系统优化设计 被引量:2

Optimum design of γ-CT system based on Geant4 simulation for multiphase flow measurement
原文传递
导出
摘要 基于蒙特卡罗方法的粒子输运模拟软件包Geant4构建低能γ射线多相流CT系统仿真模型,通过散射光子比、图像相关系数及相对图像误差等优化指标分析,对γ-CT系统的准直器、射线源数及探测器阵列单元数进行优化设计。实验结果表明,优化后系统散射光子比小于5%,明显提高检测信号灵敏度的信噪比。 A low-energy multiphase γ-CT system model was designed by using the Geant4 simulation software toolkits. According to scattering photon rate, image correlation coefficient and relative image error, designs of the collimators, the number of radiation sources and the number of detectors were optimized. The γ-CT system has a scattering photon rate of better than 5%, high measurement sensitivity and high signal-to-noise ratio, as confirmed by measurements with different flow patterns (core flow, bubbly flow, annular flow and stratified flow).
出处 《核技术》 CAS CSCD 北大核心 2011年第8期575-580,共6页 Nuclear Techniques
基金 国家自然科学基金重点项目(60532020) 国家自然科学基金重大国际合作项目(608220106002) 国家自然科学基金委员会与中国民用航空总局联合项目(60672170)
关键词 Γ射线 GEANT4 多相流 图像重建 Gamma-ray, Geant4, Multiphase flow, Image reconstruction
  • 相关文献

参考文献4

二级参考文献45

共引文献22

同被引文献21

  • 1肖雪夫,李君利,王仲奇,高文焕,夏益华,桂立明.车载式集装箱检测系统运行时环境中剂量的蒙特卡罗模拟及实验验证[J].原子能科学技术,2000,34(z1):144-147. 被引量:2
  • 2潘京生.微通道板及其主要特征性能[J].应用光学,2004,25(5):25-29. 被引量:51
  • 3曾志,李君利,程建平,邱睿.Geant4在核技术领域的应用[J].同位素,2005,18(1):55-58. 被引量:21
  • 4张多明.&nbsp&nbsp微通道板[J].物理.1986(09)
  • 5赵世诚,于长海,王黎君.微通道板X射线探测器[J]核聚变与等离子体物理,1985(03).
  • 6计算机层析成像检测[M]. 机械工业出版社, 2006.计算机层析成像检测[M]机械工业出版社,2006.
  • 7原子物理学[M]. 高等教育出版社, 2000.原子物理学[M]高等教育出版社,2000.
  • 8Umesh Kumar,G.S. Ramakrishna,A.S. Pendharkar,Gursharan Singh.Behaviour of reconstructed attenuation values with X-ray tube voltage in an experimental third-generation industrial CT system using Xscan linear detector array[J]. Nuclear Inst. and Methods in Physics Research, A . 2002 (1)
  • 9Allison, J.,Amako, K.,Apostolakis, J.,Araujo, H.,Dubois, P. Arce,Asai, M.,Barrand, G.,Capra, R.,Chauvie, S.,Chytracek, R.,Cirrone, G.A.P.,Cooperman, G.,Cosmo, G.,Cuttone, G.,Daquino, G.G.,Donszelmann, M.,Dressel, M.,Folger, G.,Foppiano.Geant4 developments and applications. IEEE Transactions on Nuclear Science . 2006
  • 10Lee, Sang Chul,Kim, Ho Kyung,Chun, In Kon,Cho, Myung Hye,Lee, Soo Yeol,Cho, Min Hyoung.A flat-panel detector based micro-CT system: Performance evaluation for small-animal imaging. Physics in Medicine and Biology . 2003

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部