摘要
抚顺新钢铁有限责任公司有40t转炉2座,30t转炉3座,1989年陆续投产以来,在实际运行中出现过各种不同的故障,根据多年来的实际运行经验,结合转炉余热锅炉的结构及工作原理,分析了转炉余热锅炉的故障原因,从运行和参数优化方面提出了预防措施。
Fushun New Steel Co. , Ltd. has 40 tons of converter 2, converter 3 30 tons, gradually put into production since 1989, appeared in the actual operation of a variety of failures, according to years of actual operating experience, combined converter vaporization of the boiler structure and working principle of the converter causes vaporization of boiler failure, from operation and parameter optimization proposed preventive measures.
关键词
转炉
汽化锅炉
故障及分析
预防措施
Converter
Gasification boiler
Failure and Analysis
Precaution