氯酸盐电解槽废气的处理

Waste gas treatment of chlorate electrolyzers
下载PDF
导出
摘要 对氯酸盐电解槽废气的产生进行分析。介绍了电解槽废气处理的工艺:经过预处理,使气体中氯气含量降低50%,再经过以氢氧化钠溶液为氯气吸收剂的串联吸收塔,可使氯气体积分数达2×10-5以下;将该气体通过以钯为催化剂、三氧化二铝为载体的除氧塔进行处理,经水环式真空泵及压缩机输送至下一工序予以利用。提出了废气处理过程中应注意的问题以及应采取的措施。 Based on the analysis about the waste gas produced from chlorate electrolyzers,waste gas treatment technology of chlorate electrolyzers was introduced as follows:firstly,content of chlorine in waste gas is reduced by 50% after pretreatment;then,volume fraction of chlorine is below 2×10-5 through the absorption columns in series,whose absorber is NaOH solution;finally,by the deoxygenization column with palladium as catalyst and Al2O3 as carrier,the gas is transported to the next procedure through water-ring vacuum pump and compressor.Some attentive problems and appropriate measures in the process of waste gas treatment were put forward.
作者 许瑞光
出处 《无机盐工业》 CAS 北大核心 2011年第8期9-10,共2页 Inorganic Chemicals Industry
关键词 氯酸盐 废气 除氯 除氧 chlorate waste gas deoxygenization dechlorination
  • 相关文献

参考文献2

  • 1中国节能产业网.碳排放的计算方法及与电的换算公式[EB/OL].2009-12-10[2011-01-10].http:/WWW.china-esi.com/pa~9079.html.
  • 2DB21/1617—2008烧碱单位产品综合能耗、交流电消耗限额及计算方法[S].