用钙试剂羧酸钠为指示剂络合滴定法测定降水中钙离子 被引量:6

Determination of the Calcium Ion in the Rain by Complex Titration with the Indicator Ca Reagent Carboxylic Acid Sodium
下载PDF
导出
摘要 提出用钙试剂羧酸钠作指示剂络合滴定法测定降水中钙离子 ,在自然条件下终点的观察即能顺利进行。同《空气和废气监测分析方法》中钙离子络合滴定法相比较 ,此法终点敏锐 ,回收率为 95 %~ 1 0 0 % ,相对标准偏差均小于 2 .7% ,方法简便、快速、准确、灵敏。具有推广性。 Using the Ca reagent carboxylic acid Na as the indicator for the determination of calcium ion in the rain was reported. The whole experiment can be carried out under the natural condition. Compared to the complex titration for the calcium ion commenced in the (Superrising & Analysis of Air & Waste Gas), the end point is sensitive. The recoveries were from 95.0% to 100%, and the relative standard deviations were less than 2.7%. The advantages of this method are simple, rapid, accurate and sensitive.
作者 吴泽惠
出处 《分析科学学报》 CAS CSCD 1999年第6期498-501,共4页 Journal of Analytical Science
关键词 配合滴定 钙试剂羧酸钠 降水 钙离子 Ca reagent carboxylic acid Na, Complex titration, Rain, Calcium ion
  • 相关文献

参考文献5

  • 1张宁,中国环境监测,1994年,29页
  • 2中国环境保护局,空气和废气监测分析方法,1990年,317页
  • 3中国环境保护局,水和废水监测分析方法(第3版),1989年,221页
  • 4杨德俊,络合滴定的理论和应用,1965年,105页
  • 5杨德俊,络合滴定的理论和应用,1965年,119页