摘要
提出用钙试剂羧酸钠作指示剂络合滴定法测定降水中钙离子 ,在自然条件下终点的观察即能顺利进行。同《空气和废气监测分析方法》中钙离子络合滴定法相比较 ,此法终点敏锐 ,回收率为 95 %~ 1 0 0 % ,相对标准偏差均小于 2 .7% ,方法简便、快速、准确、灵敏。具有推广性。
Using the Ca reagent carboxylic acid Na as the indicator for the determination of calcium ion in the rain was reported. The whole experiment can be carried out under the natural condition. Compared to the complex titration for the calcium ion commenced in the (Superrising & Analysis of Air & Waste Gas), the end point is sensitive. The recoveries were from 95.0% to 100%, and the relative standard deviations were less than 2.7%. The advantages of this method are simple, rapid, accurate and sensitive.
出处
《分析科学学报》
CAS
CSCD
1999年第6期498-501,共4页
Journal of Analytical Science
关键词
配合滴定
钙试剂羧酸钠
降水
钙离子
Ca reagent carboxylic acid Na, Complex titration, Rain, Calcium ion