摘要 应用扫描微参比电极(SMRE)技术,对NaCl溶液中印刷电路板Cu/焊锡界面局部腐蚀早期表面微区电位分布进行了测量。结果表明,在0.5 mol/L NaCl溶液中,焊锡电极电位基本稳定在-0.47 V(SCE)附近,纯铜电极的电位稳定在-0.19V(SCE)附近,两者差别较大;Cu/焊锡浸入0.5 mol/L NaCl溶液中,前期局部腐蚀发生在Cu与焊锡接触的界面上,且腐蚀程度随时间逐渐达到最大;以后焊锡作为阳极腐蚀逐渐加剧,而铜作为阴极受到保护,腐蚀程度逐渐减弱,直至焊锡最终全面腐蚀。 The localized corrosion in the early stage of Cu/solderingtin interface was observed by scanning micro reference electrode (SMRE) technique. SMRE results showed that the corrosion of Cu/soldering tin didn' t occur immediately after immersed in 0.5 mol/L NaC1 solution. The localized corrosion took place after immersed for about half an hour. With the immersion time extended to four hours, the localized corrosion occured in the interface of Cu and soldering tin, and the degree of corrosion reached the maximum. When immersion time was between five and six hours, the corrosion of the interface and soldering tin became worse gradually. After seven hours, galvanic corrosion was even more remarkable. The soldering tin as an anode was corroded gradually and the copper as a cathode was protected.
出处 《腐蚀与防护》 CAS 北大核心 2011年第8期658-660,672,共4页 Corrosion & Protection
关键词 印刷电路板 Cu/焊锡 扫描微参比电极 局部腐蚀 printed circuit board Cu/solderingtin SMRE localized corrosion
  • 相关文献

参考文献6

二级参考文献8

  • 1邸柏林.论钢铁的铝锌合金热浸镀层[J].表面技术,1994,23(1):1-5. 被引量:19
  • 2黄永昌,金属腐蚀与防护原理,1989年
  • 3曹楚南,腐蚀试验数据的统计分析,1988年
  • 4刘永辉,电化学测试技术,1987年
  • 5林爱玲,中国腐蚀与防护学报,1986年,2卷,6期,81页
  • 6孟容详,中国腐蚀与防护学报,1986年,2卷,6期,91页
  • 7曹楚南,腐蚀电化学原理,1985年
  • 8郭瑞金,火时中.小孔腐蚀诱发过程的研究[J]中国腐蚀与防护学报,1986(02).

共引文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部