中孕中期胎儿动脉导管参考值范围的建立及其意义 被引量:7

Establishment and value of reference range for fetal ductus arteriosus during mid-second trimester
下载PDF
导出
摘要 目的建立二维心脏超声在中孕中期(20周~23+6周)胎儿动脉导管(ductus arteriosus,DA)内径的参考值范围。方法 2009年1月至2010年5月期间在复旦大学附属妇产科医院进行产前筛查的单胎孕妇4 456例,同时进行胎儿心脏超声,测量DA内径,统计各孕周DA内径参考值范围。结果 4 456例中孕中期胎儿中,4 403例DA显示清晰,DA的显示率为98.81%;各孕周DA测量数据呈正态分布,20周~23+6周的均数为(2.27±0.42)mm^(2.53±0.33)mm;第50百分位数为2.3~2.5 mm。结论中孕中期能够观察到胎儿DA,并能进行管径测量。DA内径参考值的建立可能对早期发现DA异常及DA相关疾病有所帮助。 Objective To establish reference range for the diameter of fetal ductus arteriosus(DA) during mid-second trimester.Methods Two dimensional echocardiography was performed at 20 to 23+6 weeks in 4 456 singleton fetuses from Jan.2009 to May 2010.Inner diameter of DA was measured.Results DA was displayed clearly in 4 403 out of 4 456 cases,and the display rate of DA was 98.81%.The measured values of DA diameter was normally distributed and increased with gestational age.The mean value of DA diameter was(2.27±0.42)mm to(2.53±0.33)mm,and the 50th percentile was 2.3 to 2.5 mm at 20 to 23+6 weeks.Conclusions It is possible to observe DA and measure its diameter during mid-second trimester.The reference range for DA diameter in fetus may be helpful for early diagnosis of DA-related heart disease.
出处 《复旦学报(医学版)》 CAS CSCD 北大核心 2011年第4期300-302,共3页 Fudan University Journal of Medical Sciences
基金 国家高技术研究发展计划(863计划)项目(2007AA02Z442)
关键词 中孕中期 胎儿 超声心动图 动脉导管 参考值范围 mid-second trimester fetal echocardiography ductus arteriosus reference range
  • 相关文献

参考文献8

  • 1International Society of Ultrasound in Obstetrics and Gynecology. Cardiac screening guidelines of the fetus: guidelines for performing the ' basic' and ' extended basic' cardiac scan[J]. Ultrasound Obstet Gynecol, 2006,27(1) :107 - 113.
  • 2付俊峰,张荣和,徐云峰,赵夏,王玲,陈宝国,张源祥.胎儿动脉导管的超声观测及其意义[J].中国临床解剖学杂志,2008,26(5):513-516. 被引量:20
  • 3Mielke G, Benda N. Reference ranges for two-dimensional echocardiographic examination of the fetal ductus arteriosus [J]. Ultrasound Obstet Gynecol,2000,15(3):219- 225.
  • 4Paladini D,Marasini M,Volpe P. Severe ductal constriction in the third-trimester fetus following maternal self-medication with nimesulide[J]. Ultrasound Obstet Ggneeol , 2005,25 (4) :357 - 361.
  • 5朱梅,刘传玺,李垂平,王月美.彩色多普勒超声诊断胎儿动脉导管早闭[J].中华超声影像学杂志,2004,13(4):278-280. 被引量:30
  • 6Tseng JJ,Jan SL. Fetal echocardiographic diagnosis of isolated ductus arteriosus aneurysm: a longitudinal study from 32 weeks of gestation to term [J ]. Ultrasound Obstet Gynecol, 2005,26 (1) : 50 - 56.
  • 7严燕琼,付俊峰,张荣和.中孕期胎儿心脏动脉导管的测量[J].现代医院,2008,8(7):69-69. 被引量:6
  • 8刘爽,赵丽春,徐淑波,李百玲,张小辉,李卓.应用胎儿超声心动图技术早期诊断动脉导管依赖型先天性心脏病[J].吉林医学,2008,29(7):547-549. 被引量:7

二级参考文献20

  • 1孙建华,李菁,黄萍,步军,贝斐.前列腺素E_1新制剂在新生儿先心病术前的疗效[J].上海第二医科大学学报,2005,25(7):738-740. 被引量:5
  • 2曾慧茹,赵金惠,刘彤,李玲.超声心动图指标预测新生儿动脉导管自然关闭的价值[J].中国临床医学影像杂志,2006,17(1):39-41. 被引量:4
  • 3郑文丽.动脉导管未闭的超声心动图诊断[J].内科,2007,2(2):281-282. 被引量:3
  • 4林其珊,卢爱平,樊绍曾,孙斌,陈伟达.新生儿及早产儿动脉导管未闭的诊断及左室功能评估[J].中国实用儿科杂志,1997,12(1):25-26. 被引量:3
  • 5[3]SHEN C T,KUA K E,WANG N K.Prognostic value of color Doppler,echoeardiographie findings in premature newborns with patent duetus arteriosus[J].Zhonghua Min Guo Xiao Er Ke Yi Xue Hui Za Zhi,1997,38 (2):104-110.
  • 6Vinals F, Tapia J. Prenatal detection of ductal - dependent congenital heart disease[ J]. Ultrasound Obstet Gynecol,2002,19 : 246.
  • 7Tworetzky W, Wilkins - Hang L, Jennings RW. Balloon dilation of severe aortic stenosis in the fetus. Potential for prevention of hypoplastic left heart syndrome. Candidate Selection, Technique, and Results of Successful Intervention [ J ]. Circulation, 2004,110:2125.
  • 8Mary T. Innovations in fetal cardiology: medical and catheter intervention therapy[ J ]. Heart Views ,2005,6 ( 1 ) :88.
  • 9Kohl T, Sharland G, Alien L, et al. World experience of percutaneous ultrasound guided balloon valvuloplasty in human fetuses with severe aortic valve obstruction [ J ]. Am J Cardiol, 2000, 85 : 1230.
  • 10Tworetzky W,Wilkins- Haug L, Jennings RW,et al. Balloon dilation of severe aortic stenesis in the fetus. Potential for prevention of hypoplastic left heart syndrome. Candidate Selection, Technique, and Results of Successful Intervention[ J ]. Circulation, 2004,110:2125.

共引文献46

同被引文献41

  • 1赵胜.ISUOG胎儿心脏超声检查指南(修订版)[J].中国产前诊断杂志(电子版),2014(1):46-54. 被引量:13
  • 2朱若燕,桂永浩,李丽蟾,陈瑞玉,孙莉,常才.胎儿超声心动图检查的多中心临床评价[J].中华儿科杂志,2006,44(10):764-769. 被引量:7
  • 3钱敏,孙燕,陈焰.胎儿动脉导管水平面和矢状面测量方法比较[J].中华妇产科杂志,2007,42(4):259-259. 被引量:2
  • 4International Society of Ultrasound in Obstetrics and Gynecology. Cardiac screening guidelines of the fetus: guidelines for performing the 'basic' and 'extended basic' cardiac SEAS. Ultrasound Obstet Gynecol, 2006, 27( 1 ): 107-113.
  • 5Mielke G, Benda N. Reference ranges for two-dimensional echocardiographic examination of the fetal ductus arteriosus. Ultrasound Obstet Gynecol, 2000, 15(3):219-225.
  • 6Paladini D, Marasini M, Volpe P. Severe ductal constriction in the third-trimester fetus following maternal self-medication with nimesulide. Ultrasound Obstet Gynecol, 2005, 25(4):357-361.
  • 7CM Jackson, GGS Sandor, K Lim,et,al.Diagnosis of fetal ductus arteriosus aneurysm: importance of thethree-vessel view.Ultrasound in Obstetrics & Gynecology,2005,26(1):57-62.
  • 8Sheridan RM, Micheifelder EC, Choe KA, et al. Ductus arteriosus aneurysm with massive thrombosis ofpulmonary artery and fetalhydrops. Pediatr Dev Pathol,2012,15(1):79-85.
  • 9Jan SL5Chan SCFu YC.Elastin gene study ofinfants with isolated congenital ductus arteriosus aneurysm.Acta Cardiologica,2009,64(3):363-369.
  • 10张丽娜,廖平川,裴秋艳,刘望彭,裴劲松.超声探测正常孕20~40周胎儿卵圆孔的初步研究[J].中国超声医学杂志,2008,24(5):456-458. 被引量:14

引证文献7

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部