摘要 考虑移动气象台一般由通信指挥和车载雷达两部分组成,结合其移动和停放时的相对固定特点,对可能遭受雷击的种类作了详细分析。以国家防雷标准、气象和通信行业现行标准为基础,对移动气象台防雷进行层层防雷设置,综合治理,同时还对防雷安装施工方法进行了具体探讨,对做好移动气象台的防雷工作都具有一定的指导意义。 Considering the mobile meteorological station is normally provided by communication and command and car of radar,combining with its relative fixed characteristics when mobile and parked,the possible type of lightning shock were analyzed in detail.On the basis of standards of mobile and the national meteorological and communications industry,the lightning protective devices were set and managed comprehensively for mobile meteorological station.At the same time,the lightning protection installation and construction methods were discussed in detail.Those has some guidance on the good work of mobile meteorological station.
作者 陈红兵 徐文
出处 《现代建筑电气》 2011年第6期43-48,共6页 Modern Architecture Electric
关键词 移动气象台 防雷 雷达车 引下线 mobile meteorological station lightning protection radar truck downlead
  • 相关文献

参考文献5

  • 1JGJ 16-2008 民用建筑电气设计规范[S].
  • 2GB50343-2004.建筑物电子信息系统防雷技术规范[S].[S].,..
  • 3GB50057-1994.建筑物防雷设计规范[S].[S].,..
  • 4QX2-2000.新一代天气雷达站防雷技术规范[S].
  • 5YD5068-1998移动通信基站防雷与接地设计规范[S].