期刊文献+

二维电离室矩阵在IMRT中的剂量学验证 被引量:3

下载PDF
导出
摘要 本文简要介绍了IBA二维电离室矩阵MatriXX系统在IMRT剂量学验证中的应用,特别是在单个照射野中二维剂量分布的验证和IMRT剂量分布的验证,通过验证我们发现它是IMRT质量保证的重要工具,也是实施IMRT治疗过程中的可靠保证。MatriXX作为一种快速的剂量测量系统,可以在短时间内获取大量照射野剂量学方面的数据信息,能够很好的满足临床IMRT治疗时的测量需要。
出处 《医疗装备》 2011年第8期4-6,共3页 Medical Equipment
  • 相关文献

参考文献10

  • 1于金明,李宝生.调强放射治疗的临床应用现状与存在的问题[J].中华肿瘤杂志,2005,27(3):188-190. 被引量:43
  • 2Dong L, Antolak J, Salehpour M, et al. Patient - specific point dose measurement for IMRT monitor unit verification [J] . Int J Radiat Oncol Biol Phys, 2003, 56 (3): 867 - 877.
  • 3马金利,蒋国樑.调强适形放射治疗剂量学验证体系的建立[J].中国肿瘤,2004,13(8):485-489. 被引量:8
  • 4Amero S, Boriano A, Bourhaleb F, et al. Dosimetric characterization of a large pixel - segment ionization chamber [J] . MedPhys, 2004, 31 (2): 414-420.
  • 5Laub WU, Wong T . The volume effect of detectors in the dosimetry of small fields used in IMRT [ J ] . Med Phys, 2003, 30 (3): 341-347.
  • 6Stock M, Kroupa B, Georg D. Interpretation and evaluation of the gamma index and gamma Index angle for the verification of IMRT hybrid plans [ J ] . Phys Med Biol, 2005, 50 (3): 399-411.
  • 7Ezzell GA, Galvin JM, Low D, et al. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee [ J ] .Med Phys, 2003, 30 (8): 2089-2115.
  • 8Dinesh M, Thirumavalavan N, Babaiah M, et al. QA of intensitymodulated beams using dynamic MLC log files [J] . MedPhys, 2006, 31 (1): 36-41.
  • 9Stasi M, Giordanengo S, Cirio R, et al. D - IMRT verification with a 2D pixel ionization chamber: dosimetric and clinical results in head and neck cancer [ J ] . Phys Med Biol, 2005, 50 (19): 4681-4694.
  • 10周振山,于广辉,乔艳萍.调强放射治疗计划的剂量验证[J].中华放射医学与防护杂志,2005,25(1):69-70. 被引量:5

二级参考文献23

  • 1Leal A, Sanchez D, Arrans R, et al. Routine IMRT verification by means of an automated Monte Carlo simulation system. Int J Radiat Oncol Biol Phys,2003, 56: 58-68.
  • 2Chang J, Mageras GS, Ling CC. Evaluation of rapid dose map acquisition of a scanning liquid-filled ionization chamber electronic portal imaging device. Int J Radiat Oncol Biol Phys, 2003, 55: 1432-1445.
  • 3De-Deene Y. Dosimetry for the dose verification of intensity modulated radiotherapy treatments. Z Med Phys, 2002, 12: 77-88.
  • 4Zhu XY, Jursinic PA, Grimm DF, et al. Evaluation of Kodak EDR2film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Med Phys, 2002, 29: 1687-1692.
  • 5Dogan N, Leybovich LB, Sethi A. Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy. Phys Med Biol, 2002 ,47: 4121-4130.
  • 6Bjarngard BE, Kijewski PK, Pashby C. Description of a computer controlled machine. Int J Radiat Oncol Biol Phys, 1977, 2:142.
  • 7Uy NW, Woo SY, Teh BS, et al. Intensity-modulated radiation therapy (IMRT) for meningioma. Int J Radiat Oncol Biol Phys, 2002,53:1265-1270.
  • 8Fuss M, Salter BJ, Sadeghi A, et al. Fractionated stereotactic intensitymodulated radiotherapy (FS-IMRT) for small acoustic neuromas. Med Dosim, 2002,27:147-154.
  • 9Butler EB, Teh BS, Grant WH, et al. SMART (simultaneous modulated accelerated radiation therapy ) boost: a new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy. Iht J Radiat Oncol Biol Phys, 1999,45:21-32.
  • 10Chao KS, Ozyigit G, Tran BN, et al. Patterns of failures in patients receiving definitive and postoperative IMRT for head-and-neck cancer. Int J Radiat Oncol Biol Phys, 2003,55:312-321.

共引文献51

同被引文献19

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部