摘要 目的:探讨320排640层动态容积CT冠状动脉成像的图像质量和诊断冠状动脉狭窄≥50%的准确性。方法:采用320排640层CT对临床224例连续性病例进行心电门控宽探测器平台下全器官容积增强扫描,其中27例有冠状动脉造影与冠状动脉CTA作为对照。结果:Ⅰ级图像198例(88.39%),Ⅱ级21例(9.30%),Ⅲ级5例(2.23%)。全部病例无阶梯伪影,运动伪影26例。320排640层动态容积CT冠状动脉成像诊断冠状动脉狭窄≥50%的敏感性、特异性分别为96.59%、98.74%。结论:320排640层动态容积CT冠状动脉成像图像质量高,对诊断冠状动脉狭窄≥50%有较高的敏感性和特异性。
机构地区 解放军
出处 《医疗装备》 2011年第8期10-13,共4页 Medical Equipment
  • 相关文献

参考文献1

二级参考文献10

  • 1张竹花 金征宇 李冬晶 等.多层螺旋CT冠状动脉成像研究[J].中华放射学杂志,2003,37(9):147-147.
  • 2Nieman K,Cademartiri F,Lemos PA,et al.Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.Circulation,2002,106:2036-2038.
  • 3Ropers D,Baum U,Pohle K,et al.Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.Circulation,2003,107:664-666.
  • 4Flohr TG,Schoepf UJ,Kuettner A,et al.Advances in cardiac imaging with 16-section CT systems.Acad Radiol,2003,10:386-401.
  • 5Detre KM,Wright E,Murphy ML,et al.Observer agreement in evaluating coronary angiograms.Circulation,1975,52:979-986.
  • 6Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated for coronary artery disease.Report of the Ad-Hoc Committee for Grading of Coronary Artery Disease,Council on Cardiovascular Surgery.Circulation,1975,51:5-40.
  • 7Nieman K,Rensing BJ,van Geuns RJM,et al.Non-invasive coronary angiography with multislice spiral CT:the impact of heartrate.Heart,2002,88:470-474.
  • 8Mollet NR,Cademartiri F,Krestin GP,et al.Improved diagnosticccuracy with 16-row multi-slice computed tomography coronary angiography.J Am Coll Cardiol,2005,45:128-132.
  • 9Cademartiri F,Nieman K,van der Lugt A,et al.Intravenous contrast material administration at 16-detector row helical CT coronary angiography:test bolus versus bolus-tracking technique.Radiology,2004,233:817-823.
  • 10Beck T,Kuettner A,Burgstahler C,et al.Noninvasive detection of coronary stenosis using 16-slice detector computed tomography incarefully selected patients.Med Klin (Munich),2004,99:45 -650.

共引文献98

同被引文献37

  • 1Michael L, Steigner O, Hansel J, et al. Narrowing thephase window width in prospectively ECG- gated singleheart beat 320 - detector row coronary CT anglography: J)..lnt J Cardiovasc Imaging, 2009, 25 ( 1 ) : 85 - 90.
  • 2Weigold W. G. Coronary CT Angiography; Insights Into Pa - tient Preparation and scanning[ J:. Techniques in Vascular andlnterventional Radiology, 2006,9 (4) : 205 - 209.
  • 3门肾力,陈为军.320排cT冠脉造影防对比剂渗漏的注意事项[J].医疗装,2011,24(6):35.
  • 4Boll DT, Merkle EM, Paulson EK, et al. Coronary stent paten- cy: Dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom. Radiology, 2008,247(3) :687-695.
  • 5Maintz D, Grude M, Fallenberg EM, et al. Assessment of coro- nary arterial stents by multislice-CT angiography. Acta Radiol, 2003,44 (6) : 597-603.
  • 6Rybicki FJ, Otero H J, Steigner ML, et aI. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging, 2008,24(5) : 535-546.
  • 7孙昊,高明明,马展鸿,张镭,杨新春,迟永辉,薛永利,巫琳,王彦江.冠状动脉钙化对64层螺旋CT诊断冠状动脉狭窄的影响[J].中华放射学杂志,2007,41(10):1023-1027. 被引量:34
  • 8王超琴,刘延锦,李素兰.高压静脉注射造影剂药液外渗与注射部位相关性研究[J].护士进修杂志,2007,22(15):1357-1358. 被引量:55
  • 9NASIS A, MICHAEL C, PAUL R. Diagnostic accuracy of noninvasive coronary angiography with 320-detector row computed tomography [ J ]. Am J Cardiol,2010,106 ( 10 ) : 1429.
  • 10韩勤甫,王淑红,贾银明,申娟,金培印,张海柱,陈悦,吕燕.多层螺旋CT冠脉成像与导管法冠状动脉造影对比观察[J].中国现代医学杂志,2008,18(3):370-372. 被引量:13

引证文献5

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部