期刊文献+

切开复位内固定治疗不稳定型桡骨远端骨折36例观察 被引量:2

下载PDF
导出
摘要 目的:观察手术治疗不稳定型桡骨远端骨折的临床疗效。方法:采用切开复位内固定治疗不稳定型桡骨远端骨折36例并观察其治疗效果。结果:优22例,良10例,可3例,差1例。优良率88.89%。结论:切开复位内固定治疗不稳定型桡骨远端骨折有较好疗效。
机构地区 大邑县骨科医院
出处 《现代临床医学》 2011年第4期286-287,共2页 Journal of Modern Clinical Medicine
  • 相关文献

参考文献5

二级参考文献37

  • 1陈国奋,土井一辉,顾立强,裴国献.桡骨远端关节内骨折的分类与关节镜下复位固定[J].中华创伤骨科杂志,2004,6(10):1167-1170. 被引量:17
  • 2姜保国.桡骨远端骨折的治疗[J].中华创伤骨科杂志,2006,8(3):236-239. 被引量:185
  • 3Hanel DP, Jones MD, Trumble TE. Treatment of complex fractures,wrist fractures, Orthop Clin North Am, 2002 ;33 : 35.
  • 4Dienst M, Wozusek GE, Seligson D. Dynamic extermal fixation for distal radius fractures. Clin Orthop, 1997; 338 : 160.
  • 5Collert S, Isacson J. Management of redislocated Colles, fractures. Ciln Orthop, 1978 ; 135 : 183 - 186.
  • 6Kazuki K, Kusunoki M, Shimazu A. Pressure dist ribution int he radial carpal joint measured with a densitometer designed for pressure sensitive film. J Hand Surg Am,1991,16(3) :4012408.
  • 7Baratz ME, Des jardins JD, Anderson DD, et al. Disolaced intra - articular fractures of the distal radius : the effect of frac2ture displacement on contact stesses in a cadaver model. J Hand Surg ( Am ), 1996 ; 21 ( 2 ) : 1832188.
  • 8Knir KJL, Jupiter JB. Intra - articular fractures of the distal end of the radius in young adults. J Bone Joint Surg( Am), 1996 ;68:647.
  • 9Trumble TE. Culp RW, Hanel DP. Int ra2articular fractures of the distal aspect of the radius. Instr Course L ect, 1999 ;48 (6) :4652480.
  • 10Hanel DP, Jones MD, Trumble TE. Treatment of complex fractures. wrist fractures. Orthop Clin North Am,2002,33 (1) :35.

共引文献223

同被引文献14

  • 1WATERS PM, MINTZER CM, HIPP JA, et al. Noninvasive measurement of distal radius instability[ J]. J Hand Surg Am, 1997, 22(4) : 572 -579.
  • 2Jupiter JB. Fractures of the distal and of the radius [ J ]. J Bone Joint Surg, 1991,73:461 -469.
  • 3GREWAL R, PEREY B, WILMINK M, et al. A randomized prospective study on the treatment of intra - articular distal radius fractures: open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation, and external fixation [ J ]. J Hand Surg Am, 2005, 30 (4) : 764 -772.
  • 4GARTLAND JJ, WERLEY CW. Evaluation of healed Colles' fractures[J]. J Bone Joint Surg Am, 1951, 33 -A(4): 895 - 907.
  • 5JACOBI M, WAHL P, KOHUT G. Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio -volar double plating technique [ J ]. J Orthop Surg Res, 2010, 5: 55.
  • 6CAPO JT, ROSSY W, HENRY P, et al. External fixation of distal radius fractures : effect of distraction and duration [ J ]. J Hand Surg Am, 2009, 34(9) : 1605 - 1611.
  • 7沈忆新,郑祖根.桡骨远端骨折动力型外固定器的设计和应用[J].中华骨科杂志,1999,19(3):157-160. 被引量:81
  • 8任国文,吴学元.复杂桡骨远端骨折的手术治疗[J].中国骨与关节损伤杂志,2011,26(3):254-255. 被引量:23
  • 9朱乐银,印文彩,乔高山,夏建忠.掌侧入路斜T形钢板内固定治疗桡骨远端不稳定骨折[J].临床骨科杂志,2012,15(1):95-97. 被引量:32
  • 10胡东山,罗逸林.掌侧锁定加压钢板治疗桡骨远端关节内骨折50例[J].中国老年学杂志,2013,33(7):1689-1690. 被引量:11

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部