摘要
基于活性氧化铝除氟的离子交换机理,考虑我国高氟水区比较偏远、分散的实情,确定固定床活性氧化侣除氟主要设计参数、工艺计算方法和设计注意事项.
Based on the theory of ion exchange in the defluorinating process by using activated alumina and considering the reality that the areas where raw water has high concentration of fluorine are remote and scattered in China,the designing parameters,the designing formulae of the technolgoical device and the designing points for attention are determined.
出处
《西北建筑工程学院学报(自然科学版)》
1999年第4期43-48,共6页
Journal of Northwestern Institute of Architectural Engineering
关键词
活性氧化铝
除氟
滤料
离子交换
饱用水
activated alumina
defluorinate
filtration medium
ion exchange