螺纹联接应用广泛,防松问题受到了人们的关注。本文通过对不同预紧力下的双螺母联接,在紧固件横向振动实验装置上进行了试验,总结出双螺母联接中不同预紧力下的防松效果与两个螺母之间预紧力的关系。
The threaded connection is widely applied,and anti-loosening has been concerned by people.Double nuts anti-loosening experiment was conducted by fasteners transverse vibration test machine,through double nut connection under different pre-tightening force,and the relation of anti-loosening effect under different pre-tightening force and the pre-tightening force between two nuts was summarized in this article.